2013
DOI: 10.1016/j.scitotenv.2013.01.029
|View full text |Cite
|
Sign up to set email alerts
|

Partition of perfluoroalkyl substances (PFASs) in whole blood and plasma, assessed in maternal and umbilical cord samples from inhabitants of arctic Russia and Uzbekistan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

7
103
6

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 132 publications
(117 citation statements)
references
References 38 publications
7
103
6
Order By: Relevance
“…Short-chain (PFBA and PFPeA) and long-chain PFASs (PFTrA, PFTeA, PFHxDA and PFODA) were not all detected in several previous studies due to poor peak shape or blank contamination, which resulted in unsatisfactory LODs or recoveries. In the present study, the LODs of short-chain PFASs (PFBA and PFPeA) and long-chain PFASs (PFTrA, PFTeA, PFHxDA and PFODA) were 0.008, 0.022, 0.045, 0.058, 0.15 and 0.19 ng mL −1 , respectively, which were much lower than those of previous studies [1,11,23,25,27,35], the LODs of PFBA, PFPeA, PFTrA, PFTeA, PFHxDA and PFODA were 0.35, 0.76, 0.32, 0.22, 0.53 and 0.42 ng mL −1 , respectively, in Llorca et al's study [27], and the LODs of PFBA, PFPeA, PFTrA, PFTeA, PFHxDA and PFODA in our traditional MTBE method were 0.035, 0.031, 0.19, 0.23, 0.27 and 0.32 ng mL −1 , respectively. The low LODs of short-and long-chain PFASs in the present study might result from our efforts to improve the peak shape of analytes and blank contamination control during the detection process.…”
Section: Validation Of the Methods And Performance With Serum Samplescontrasting
confidence: 80%
See 4 more Smart Citations
“…Short-chain (PFBA and PFPeA) and long-chain PFASs (PFTrA, PFTeA, PFHxDA and PFODA) were not all detected in several previous studies due to poor peak shape or blank contamination, which resulted in unsatisfactory LODs or recoveries. In the present study, the LODs of short-chain PFASs (PFBA and PFPeA) and long-chain PFASs (PFTrA, PFTeA, PFHxDA and PFODA) were 0.008, 0.022, 0.045, 0.058, 0.15 and 0.19 ng mL −1 , respectively, which were much lower than those of previous studies [1,11,23,25,27,35], the LODs of PFBA, PFPeA, PFTrA, PFTeA, PFHxDA and PFODA were 0.35, 0.76, 0.32, 0.22, 0.53 and 0.42 ng mL −1 , respectively, in Llorca et al's study [27], and the LODs of PFBA, PFPeA, PFTrA, PFTeA, PFHxDA and PFODA in our traditional MTBE method were 0.035, 0.031, 0.19, 0.23, 0.27 and 0.32 ng mL −1 , respectively. The low LODs of short-and long-chain PFASs in the present study might result from our efforts to improve the peak shape of analytes and blank contamination control during the detection process.…”
Section: Validation Of the Methods And Performance With Serum Samplescontrasting
confidence: 80%
“…However, in contrast with the analysis of the standard solutions in acetonitrile or water, the serum samples always showed matrix effects. In present study, 13 isotope-labeled internal standards have been used to correct matrix effects on ionization efficiency as well as to compensate for variation in injection, signal variation due to ion suppression or signal enhancement [4,5,14,16,23,26].…”
Section: Validation Of the Methods And Performance With Serum Samplesmentioning
confidence: 99%
See 3 more Smart Citations