2007
DOI: 10.1016/j.talanta.2006.05.091
|View full text |Cite
|
Sign up to set email alerts
|

Particle isolation for analysis of uranium minor isotopes in individual particles by secondary ion mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
59
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 74 publications
(59 citation statements)
references
References 8 publications
0
59
0
Order By: Relevance
“…[8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] The methods and procedures were validated, for example, by the use of reference materials certified by NBL (New Brunswick Laboratory) such as CRM111A ( 233 U 29 for validation of the developed bulk and particle analytical methods. The JAEA's measurement results and capabilities were proved to be excellent in the comparisons.…”
Section: Validation Of Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] The methods and procedures were validated, for example, by the use of reference materials certified by NBL (New Brunswick Laboratory) such as CRM111A ( 233 U 29 for validation of the developed bulk and particle analytical methods. The JAEA's measurement results and capabilities were proved to be excellent in the comparisons.…”
Section: Validation Of Methodsmentioning
confidence: 99%
“…In order to overcome the problem in SIMS method, we developed a method to pick up individual particle containing U or fissile materials by micro-manipulation in SEM-EDX (scanning electron microscope-energy dispersive X-ray analysis) (see Figure 3 left). [14][15][16] For the FT-TIMS method, it is easy to observe FT by an optical microscope and to collect the particles separately (see Figure 3 right). [21][22][23] This method enables us to selectively detect highly enriched U particles, which is critical in the nuclear safeguards.…”
Section: Daily Inspectionmentioning
confidence: 99%
“…[3][4][5][6][7][8][9][10][11][12] The SIMS allows us to analyze samples easily and rapidly. A main drawback in SIMS is molecular ion interferences by other elements in other particles.…”
Section: -2mentioning
confidence: 99%
“…As an alternative method, we developed a technique by a combination of particle manipulation under scanning electron microscope (SEM) and isotope ratio analysis with SIMS. 5 The particle manipulation allowed us to transfer only uranium particles for subsequent SIMS analysis, giving accurate isotope ratio results.…”
Section: -2mentioning
confidence: 99%
“…7,8 During the analysis of a uranium particle, elements such as lead (Pb) and tungsten (W) in neighboring particles may produce molecular ions and cause spectral interferences on the uranium mass region (e.g.,…”
Section: Introductionmentioning
confidence: 99%