2021
DOI: 10.1002/rcs.2352
|View full text |Cite
|
Sign up to set email alerts
|

Partial nephrectomy through retroperitoneal approach with a new surgical robot system, KD‐SR‐01

Abstract: Background: To present our experiences with partial nephrectomy (PN) through retroperitoneal approach (RP) with the Kangduo robotic system.Methods: From December 2020 to February 2021, the perioperative data of 11 patients underwent PN through RP with the Kangduo robotic system were collected prospectively.Results: For the R.E.N.A.L. nephrometry score, 72.7% of patients had a low score (4-6) and 27.3% of patients had a medium score (7-9). Seven tumours were posterior (P), four tumours were on the midline (X). … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

4
4

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 24 publications
0
13
0
Order By: Relevance
“…In fact, both robotic transperitoneal dismembered pyeloplasty and robotic partial nephrectomy using the KD-SR-01 system were feasible and safe. 21–24 We believe that transperitoneal PLND could be performed using the KD-SR-01 system safely without pelvic vessel injury, and PLND would be performed further. There were no severe (Clavien–Dindo grade ≥3) perioperative complications or major technical problems, confirming the safety of the KD-SR-01 system.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In fact, both robotic transperitoneal dismembered pyeloplasty and robotic partial nephrectomy using the KD-SR-01 system were feasible and safe. 21–24 We believe that transperitoneal PLND could be performed using the KD-SR-01 system safely without pelvic vessel injury, and PLND would be performed further. There were no severe (Clavien–Dindo grade ≥3) perioperative complications or major technical problems, confirming the safety of the KD-SR-01 system.…”
Section: Discussionmentioning
confidence: 99%
“…19,20 The KangDuo Surgical Robot-01 (KD-SR-01) system, which was recently developed in China, has shown promising results for partial nephrectomy and pyeloplasty. 21–24 To our knowledge, this is the first human clinical trial to evaluate the feasibility, safety and efficiency of the KD-SR-01 system for RARP.…”
mentioning
confidence: 99%
“…Recently, a domestic robotic platform called KD-SR-01 ® (SuZhou Kang Duo Robot Co., Ltd., Suzhou, China) has been developed. The feasibility, safety and efficacy of KD-SR-01 ® has been confirmed in radical prostatectomy and partial nephrectomy, which additionally provided short docking time and ergonomic benefits (9,10). Nevertheless, its performance in RAPA has not been assessed.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, a domestic robotic platform called KD-SR-01® (SuZhou Kang Duo Robot Co., Ltd., Suzhou, China) has been developed. The feasibility, safety and e cacy of KD-SR-01® has been con rmed in radical prostatectomy and partial nephrectomy, which additionally provided short docking time and ergonomic bene ts (9,10). Nevertheless, its performance in RAPA has not been assessed.…”
Section: Introductionmentioning
confidence: 99%