2014 ICHVE International Conference on High Voltage Engineering and Application 2014
DOI: 10.1109/ichve.2014.7035432
|View full text |Cite
|
Sign up to set email alerts
|

Partial discharge localization on dry-type transformers

Abstract: In this paper an electrical partial discharge (PD) localization technique for a dry type power transformer is presented. The method has been tested in the laboratory on real transformer coil as well as on a transformer in a test bay.Calibration signal is injected through a plate sensor placed along the winding on the surface of the transformer coil in different positions, thus PD signals can be measured at both coil terminal sites using digitizer. Measured PD signal during test can be then evaluate and compare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Unfortunately, the presented model allows only to foresee the temperature of a single point of the transformer. However, when performing a test on the transformer, for example, a short‐circuit test, one can verify that the temperature of the transformer is not homogeneous, existing in higher‐temperature zones . Therefore, in the training of the neural network, it is important not to consider an average temperature.…”
Section: Implementation Of the Proposed Toolmentioning
confidence: 99%
See 3 more Smart Citations
“…Unfortunately, the presented model allows only to foresee the temperature of a single point of the transformer. However, when performing a test on the transformer, for example, a short‐circuit test, one can verify that the temperature of the transformer is not homogeneous, existing in higher‐temperature zones . Therefore, in the training of the neural network, it is important not to consider an average temperature.…”
Section: Implementation Of the Proposed Toolmentioning
confidence: 99%
“…However, owing to their similarities, R HV and R LV were considered equal. 1 In turn, the output vector of the neural network has a single output, L T , which represents the total loss. Finally, based on the Kolmogorov method, considering the number of inputs, the maximum number of neurons in the hidden layer was set to 11.…”
Section: Total Losses Networkmentioning
confidence: 99%
See 2 more Smart Citations