2013
DOI: 10.1016/j.ijheatmasstransfer.2012.11.043
|View full text |Cite
|
Sign up to set email alerts
|

Parametric study and field synergy principle analysis of H-type finned tube bank with 10 rows

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 76 publications
(21 citation statements)
references
References 27 publications
0
19
0
2
Order By: Relevance
“…The double fin and tube heat exchanger is generally designed for a wide range of applications such as marine exhaust gas boilers for waste heat recovery from coal-fired boilers (Singh et al, 2016a(Singh et al, ,b, 2017 due to good anti-wear and anti-fouling performance, compact design, stability (Chen and Lai, 2012;Jin et al, 2013Jin et al, , 2016. To investigate the effectiveness of VGs, rectangular winglet vortex generator (RWVG) are selected considering their heat transfer enhancement performance better than delta winglets (Li et al, 2015).…”
Section: Computational Geometry: Fin and Tubementioning
confidence: 99%
“…The double fin and tube heat exchanger is generally designed for a wide range of applications such as marine exhaust gas boilers for waste heat recovery from coal-fired boilers (Singh et al, 2016a(Singh et al, ,b, 2017 due to good anti-wear and anti-fouling performance, compact design, stability (Chen and Lai, 2012;Jin et al, 2013Jin et al, , 2016. To investigate the effectiveness of VGs, rectangular winglet vortex generator (RWVG) are selected considering their heat transfer enhancement performance better than delta winglets (Li et al, 2015).…”
Section: Computational Geometry: Fin and Tubementioning
confidence: 99%
“…H-type finned tube is derived, in large part, from the rectangle-type finned tube. Because of its unique groove structure in fin surface, H-type finned tube has excellent anti-wear and anti-fouling performance [1].…”
Section: Introductionmentioning
confidence: 99%
“…Tong [2], Zhang et al [3] and Yu et al [1] studied heat transfer and pressure drop characteristics of H-type finned tube bank by numerical simulation. The effects of geometric parameters and Reynolds number were examined.…”
Section: Introductionmentioning
confidence: 99%
“…H-type finned tubes are derived largely from rectangle finned tubes. Because of their unique groove structure on the fin surface, H-type finned tubes have excellent anti-wear and anti-fouling performance [1].…”
Section: Introductionmentioning
confidence: 99%
“…Tong [10], Zhang et al [11] and Yu et al [1] studied the heat transfer and pressure drop characteristics of H-type finned tube banks by numerical simulation. The effects of geometric parameters and Reynolds number were examined.…”
Section: Introductionmentioning
confidence: 99%