Abstract:In this work, the dependence of the bulk etches rate VB for CR-39detector on thetemperature T, etching time t and concentration N of the NaOH etchant solution has been studied fordetectors material types PADC. The concentration, etching time, temperatureand other conditions havebeen varied in the ranges (5.25-8.25) N, (1-5) hand (60-80) °C for PADC respectively. In this case, the thickness of material removed by etching ranges from 0.20 to 6.10𝜇m/hr for CR-39detector.The 6.25 N NaOH solution at 70°C with etch… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.