1995
DOI: 10.1021/ac00102a002
|View full text |Cite
|
Sign up to set email alerts
|

Parameter Evaluation for the Analysis of Oxide-Based Samples with Radio Frequency Glow Discharge Mass Spectrometry

Abstract: The performance of radio frequency-powered glow discharge mass spectrometry (rf-GDMS) has been evaluatedfor the direct analysis of nonconducting samples. The parameters under study are the discharge power, the discharge pressure, the sample versus exit orifice distance, and the effect of cryogenic cooling. Optimum conditions are used to evaluate some analytical figures of merit for the analysis of compacted oxide-based materials. A precision of better than 5% is obtained on all measured species in the discharg… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
20
0

Year Published

1995
1995
2017
2017

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(20 citation statements)
references
References 0 publications
0
20
0
Order By: Relevance
“…GD-SFMS instruments are currently the only GD-MS commercially available and are manufactured by Thermo Fischer Scientific with a fast-flow Grimm-type GD cell. Alternatively, time-of-flight (TOF) mass analyzers offer many interesting features: (i) quasi-simultaneous detection of a large mass range, from hydrogen to macro-molecules, 115 (ii) higher mass resolving power compared to a quadrupole MS, 116 (iii) lower cost compared to high resolution SFMS and (iv) high spectral acquisition rate that allows the measurement of transient ion signals. 117 Taking into account these unique properties of time-of-flight mass analyzers, the use of GD-TOFMS offers great potential in the area of depth profiling analysis, especially for thin layers where the composition of the sample changes rapidly with time and the quasi-simultaneous multi-analyte determination of many isotopes should be carried out at every sample depth.…”
mentioning
confidence: 99%
“…GD-SFMS instruments are currently the only GD-MS commercially available and are manufactured by Thermo Fischer Scientific with a fast-flow Grimm-type GD cell. Alternatively, time-of-flight (TOF) mass analyzers offer many interesting features: (i) quasi-simultaneous detection of a large mass range, from hydrogen to macro-molecules, 115 (ii) higher mass resolving power compared to a quadrupole MS, 116 (iii) lower cost compared to high resolution SFMS and (iv) high spectral acquisition rate that allows the measurement of transient ion signals. 117 Taking into account these unique properties of time-of-flight mass analyzers, the use of GD-TOFMS offers great potential in the area of depth profiling analysis, especially for thin layers where the composition of the sample changes rapidly with time and the quasi-simultaneous multi-analyte determination of many isotopes should be carried out at every sample depth.…”
mentioning
confidence: 99%
“…55 The various expansions in scale clearly show the minor components in the Ðrebrick sample. Semiquantitative ion beam ratio results yield concentrations that are within a factor of two of the certiÐed values.…”
Section: Some Applications Of Gdmsmentioning
confidence: 94%
“…At present, GD-SFMS instruments are the only GD-MS instruments commercially available and are manufactured by Thermo Fischer Scientific. Alternatively, TOF mass analysers offer interesting features, such as quasisimultaneous detection of a large mass range (from H to macromolecules), higher mass resolving power compared with QMS, lower cost compared with high-resolution SFMS and a high spectral acquisition rate, which allows the measurement of transient ion signals [52,53], thus offering a great potential for thin and ultrathin solid films [54]. GD-TOFMS systems are not yet commercially available, although new prototypes are currently under development in a European project (EU through FP6 contract STREP-NMP).…”
Section: Glow Discharge Mass Spectrometrymentioning
confidence: 99%