1949
DOI: 10.1063/1.1741489
|View full text |Cite
|
Sign up to set email alerts
|

Parallel-Plate Counters

Abstract: The counter characteristics of a discharge tube using plane-parallel electrodes have been investigated, particularly with regard to the short time lags inherent in the streamer type of spark which occur with such a geometry at near-atmospheric pressure. Construction details for parallel-plate counters with good counter characteristics are given. Spurious counts were minimized by an argonxylene filling mixture and the use of a univibrator quench circuit. The uncertainty in the reaction time of the counters is ±… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0
7

Year Published

1953
1953
2020
2020

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(9 citation statements)
references
References 8 publications
0
2
0
7
Order By: Relevance
“…Счетная характеристика На рис. 2 приведена типичная счетная характеристика счетчика (при TQ= 0,05 сек), полученная в работе 2 . По оси абсцисс отложена величина .напряжения на счетчике, по оси ординат -число регистрируемых импуль-сов в 1 сек.…”
Section: медные жктродыunclassified
See 2 more Smart Citations
“…Счетная характеристика На рис. 2 приведена типичная счетная характеристика счетчика (при TQ= 0,05 сек), полученная в работе 2 . По оси абсцисс отложена величина .напряжения на счетчике, по оси ординат -число регистрируемых импуль-сов в 1 сек.…”
Section: медные жктродыunclassified
“…Их счетчики имели медные электроды из тонкой фольги (50 мк), расположенные на расстоянии 5 мм друг от друга. Размер электродов 5 X 6 = 30· см 2 . Была применена довольно сложная процедура очистки электродов, без которой невозможно было, как утверждают авторы, полу-чить хорошие счетные характеристики.…”
Section: медные жктродыunclassified
See 1 more Smart Citation
“…The first gas detector taking advantage of the improved time resolution in strong uniform electric fields was the Keuffel Spark Counter, a gaseous avalanche detector with parallel plate geometry, that was introduced in 1948 [26,27]. It indeed offered a time resolution (around 1 ns) by far better than any of the Geiger-Müller Counters that were commonly used at that time (around 100 ns) [28].…”
Section: Spark Countermentioning
confidence: 99%
“…2. 27. The two components of the weighting field are plotted for a 0.3 mm gap and a 32 mm read out strip in Fig 2.19.…”
Section: (238)mentioning
confidence: 99%