Abstract: In this work, we present a new algorithm for detecting faults in grid-connected photovoltaic (GCPV) plant. There are few instances of statistical tools being deployed in the analysis of PV measured data. The main focus of this paper is, therefore, to outline a parallel fault detection algorithm that can diagnose faults on the DC-side and AC-side of the examined GCPV system based on the t-test statistical analysis method. For a given set of operational conditions, solar irradiance and module's temperature, a nu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 67 publications
(26 citation statements)
references
References 31 publications
0
26
0
Order By: Relevance
“…[85][86][87][88][89][90][91][92] When the suspicion on the wrong component is detected, the concrete strings are then evaluated using other methods. Usual configuration of large systems consists of string inverters with the middle power (about 5-10 kW) because of the problems with local shading caused by clouds movements.…”
Section: Proposed Topologymentioning
confidence: 99%
See 1 more Smart Citation
“…[85][86][87][88][89][90][91][92] When the suspicion on the wrong component is detected, the concrete strings are then evaluated using other methods. Usual configuration of large systems consists of string inverters with the middle power (about 5-10 kW) because of the problems with local shading caused by clouds movements.…”
Section: Proposed Topologymentioning
confidence: 99%
“…The problem of data evaluation is out of range of this work and is described in many publications. [85][86][87][88][89][90][91][92] When the suspicion on the wrong component is detected, the concrete strings are then evaluated using other methods.…”
Section: Proposed Topologymentioning
confidence: 99%
“…Various types of faults associated with different PV array configurations are listed in Table . The tick and cross marks indicate, respectively, the presence and absence of particular fault in specific PV array configuration.…”
Section: Comparison Of Different Pv Array Configurations On the Basismentioning
confidence: 99%
“…For faults occurring in the grid connected PV systems, a new parallel algorithm is introduced to detect the faults on the DC and AC sides utilizing data measurements evaluated with t-statistical analysis methods [39]. Different scenarios are deployed and simulated using virtual instruments-based LabVIEW software.…”
Section: Hybrid Computational Techniquesmentioning
confidence: 99%