2020
DOI: 10.3390/molecules25030629
|View full text |Cite
|
Sign up to set email alerts
|

Paper Strip and Ceramic Potentiometric Platforms Modified with Nano-Sized Polyaniline (PANi) for Static and Hydrodynamic Monitoring of Chromium in Industrial Samples

Abstract: Screen-printed membrane sensors based on the use of paper and ceramic substrates are fabricated, characterized, and used for rapid batch and continuous monitoring of CrIII in the form of CrO42− in some industrial products and wastewater samples. Strips of paper and ceramic platforms (15 × 5 mm) were covered with conductive carbon paint and then modified with polyaniline (PANI) film, to act as an ion-to-electron transducer, followed by a drop casting of plasticized poly (vinyl chloride) (PVC) Rhodamine-B chroma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 41 publications
0
14
0
Order By: Relevance
“…95 In Hassan et al's research, polyaniline with high hydrophobicity was deposited between carbon printed paper strips and the ISM. 96 Both works demonstrated successful prevention of water layer formation due to the lipophilic conducting polymers. In addition to hydrophobic solid contacts, paper-strip ISEs with LDL of 1.2 nM for Cd 2+ were reported when an ISM with a lower coefficient of diffusion (MMA-DMA) than the conventional plasticized polyvinyl chloride was used.…”
Section: ■ Heavy Metals In the Environmentmentioning
confidence: 99%
See 1 more Smart Citation
“…95 In Hassan et al's research, polyaniline with high hydrophobicity was deposited between carbon printed paper strips and the ISM. 96 Both works demonstrated successful prevention of water layer formation due to the lipophilic conducting polymers. In addition to hydrophobic solid contacts, paper-strip ISEs with LDL of 1.2 nM for Cd 2+ were reported when an ISM with a lower coefficient of diffusion (MMA-DMA) than the conventional plasticized polyvinyl chloride was used.…”
Section: ■ Heavy Metals In the Environmentmentioning
confidence: 99%
“…Subsequently, highly lipophilic conducting polymer poly­(3-octylthiophene) was inserted between the gold layer and ISM . In Hassan et al’s research, polyaniline with high hydrophobicity was deposited between carbon printed paper strips and the ISM . Both works demonstrated successful prevention of water layer formation due to the lipophilic conducting polymers.…”
Section: Paper-based Potentiometry and Voltammetrymentioning
confidence: 99%
“…Potentiometric membrane electrodes are suitable for analysis of different species as a result of their simplicity. [1][2][3][4][5][6][7][8] Considering the method for immobilizing the polymeric membrane over the electrode, various kinds of electrodes can be created such as coated wire ion selective electrodes (CW-ISEs), ion selective electrodes with liquid internal electrolyte (LIE-ISEs), and solidstate ion selective electrodes (SS-ISEs). An internal reference electrode is required in an LIE-ISE along with internal lling solution.…”
Section: Introductionmentioning
confidence: 99%
“…10 Thus, various analytical approaches have been established for chromium detection like inductively coupled plasma-atomic emission spectroscopy, Xray uorescence, atomic absorption spectroscopy, spectrophotometry, voltammetry [11][12][13][14][15][16][17] and potentiometric measurements based on ion-selective electrodes. 5,9,[18][19][20][21][22][23][24][25][26][27] Although these approaches have good sensitivity, they have disadvantages such as the high cost of routine analysis as well as tedious and time-consuming sample preparation procedure. However, several advantages are presented by the potentiometric measurements with the selective sensor including easy sampling conditions, simplicity of equipment, low cost, low limit of detection, and the relatively wide linearity range of concentration in different solutions.…”
Section: Introductionmentioning
confidence: 99%
“…In an all-integrating paper-based potentiometric setup, paper serves not only as a microfluidic sampling substrate, but also as a mechanical support for deposition of electrodes as well as the formation of sampling/detection and other functional zones depending on its design, thereby is further denoted as a paper platform. Paper-based micro electrodes are either designed as individual ISEs [115][116][117][118][119] and REs [120,121] or integrated in miniaturised potentiometric paper-based platforms [88,95,98,[122][123][124][125][126][127][128][129][130]. The development of all-integrating paper-based sensors are as portable and disposable tools for on-site ion determination of clinical/health [95,98,[128][129][130], environmental [95,124,131] and foodstuff [124,126] samples.…”
Section: All-integrating Paper-based Sensors For Potentiometric Ion Determinationmentioning