2022
DOI: 10.1016/j.aca.2022.340553
|View full text |Cite
|
Sign up to set email alerts
|

Paper-based gold nanoparticles decorated SWCNTs chemiresistive sensor for sensitive detection of As(III) based on electrochemical doping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
4
1

Relationship

1
9

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 36 publications
0
8
0
Order By: Relevance
“…To maintain device stability and minimize electrical noise, a commonly used reference electrode such as Ag/AgCl, Ag wire, or Pt wire is used as a solution gate controller and is kept at ground potential. [64][65][66] CNTs act as a sensing element in the FET device, which differs from conventional planar FETs, and their enhanced sensitivity is attributed to their reduced dimensionality and large surface-to-volume ratio, making them highly responsive to any electric bias imposed on the nanowire interface. In p-type nanobiosensors, the receptors on the nanowire interface capture positively charged analytes, resulting in an excess of holes that dominate the CNTs-FET.…”
Section: Cnt-based Fet Biosensor Working Principlementioning
confidence: 99%
“…To maintain device stability and minimize electrical noise, a commonly used reference electrode such as Ag/AgCl, Ag wire, or Pt wire is used as a solution gate controller and is kept at ground potential. [64][65][66] CNTs act as a sensing element in the FET device, which differs from conventional planar FETs, and their enhanced sensitivity is attributed to their reduced dimensionality and large surface-to-volume ratio, making them highly responsive to any electric bias imposed on the nanowire interface. In p-type nanobiosensors, the receptors on the nanowire interface capture positively charged analytes, resulting in an excess of holes that dominate the CNTs-FET.…”
Section: Cnt-based Fet Biosensor Working Principlementioning
confidence: 99%
“…[39][40][41] Among these mediators, ferrocene is commonly used because of its fast reaction with the enzyme, wide range of pH settings, and reversible electron kinetics. [42][43][44] Second-generation glucose sensors, utilizing a redox couple or mediator-based approach, have outperformed first-generation sensors since 1984 due to their sensitivity to dissolved oxygen, even at lower potentials and extreme interference ambience. The commercial product was made possible by the discovery of a screen-printing process that enabled the creation of wearable, disposable, compact, and pocket-friendly electrodes.…”
Section: Glucose Monitoring: the Sensing Mechanismsmentioning
confidence: 99%
“…A new paper-based chemiresistive sensor has been developed for the detection of As(III) using a network of single-walled carbon nanotubes (SWCNTs) with electrodeposited gold nanoparticles (AuNPs). 59 The sensor was fabricated using a water-based SWCNT ink by wax printing and vacuum deposition. The sensitivity of the sensor was improved by optimizing the volume of SWCNTs ink used in the formation of the sensing network and the sweep segment of cyclic voltammetry used for the electrochemical deposition of AuNPs.…”
Section: Detection Of Heavy Metal Ionsmentioning
confidence: 99%