2019
DOI: 10.1007/s00064-019-00623-0
|View full text |Cite
|
Sign up to set email alerts
|

Palmare winkelstabile Verplattung von Pseudarthrosen und Trümmerfrakturen des Kahnbeins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 51 publications
0
5
0
Order By: Relevance
“…Surgical gloves with their thin layer of latex are the only mechanical barrier between the patient and the operating team and are intended, apart from various (constructional-) technical requirements in an operating theatre, to protect both sides against infection [1,2]. The sterile latex surgical glove is used in a variety of disciplines, for example in gastroscopy, cardiac catheter interventions or in invasive and minimally invasive orthopedic and traumatological procedures [3,4]. According to the European Committee for Standardization (CEN) standard EN 455, the gloves produced are randomly tested for waterproofness by means of a water tightening test (1L water for 2-3 min) and tear resistance (EN 455-2) with a maximum weight of 9 N as standard.…”
Section: Introductionmentioning
confidence: 99%
“…Surgical gloves with their thin layer of latex are the only mechanical barrier between the patient and the operating team and are intended, apart from various (constructional-) technical requirements in an operating theatre, to protect both sides against infection [1,2]. The sterile latex surgical glove is used in a variety of disciplines, for example in gastroscopy, cardiac catheter interventions or in invasive and minimally invasive orthopedic and traumatological procedures [3,4]. According to the European Committee for Standardization (CEN) standard EN 455, the gloves produced are randomly tested for waterproofness by means of a water tightening test (1L water for 2-3 min) and tear resistance (EN 455-2) with a maximum weight of 9 N as standard.…”
Section: Introductionmentioning
confidence: 99%
“…Recent studies by Quadlbauer et al showed a higher union rate in stabilization of scaphoid waist nonunions with two headless compression screws or a plate compared to stabilization with only one compression screw. This study cannot confirm or disprove these results, since the majority of fixations were conducted with K-wires in our population [32,33]. The authors used the palmar locking plate for difficult bony fixations or reduction of advanced instabilities.…”
Section: Discussionmentioning
confidence: 77%
“…An arm tourniquet was applied. The volar approach between the radial artery and flexor carpi radialis (FCR) was used to expose the scaphoid [ 6 ]. An incision was started about 4 cm proximal to the wrist crease and curved to the distal scaphoid tubercle distal to the wrist crease.…”
Section: Methodsmentioning
confidence: 99%