2011
DOI: 10.1021/ic2017648
|View full text |Cite
|
Sign up to set email alerts
|

Palladium(II) and Platinum(II) Bind Strongly to an Engineered Blue Copper Protein

Abstract: Studies of palladium(II) and platinum(II) binding to well-characterized proteins contribute to understanding the influence of these metals in the environment and the body. The well-characterized apo-protein of azurin has a soft-metal binding site that may be exposed to solvent by mutation of a coordinating histidine-117 residue to glycine. Palladium(II) and platinum(II) form strong 1:1 adducts with the apo form of H117G azurin. A combination of UV-visible, CD, and ICP-MS techniques suggests that the metal bind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 57 publications
0
10
0
Order By: Relevance
“…During sample analysis sample lines were rinsed to reduce memory effects by washing sequentially with Milli-Q purified water for two minutes and 2% nitric acid for an additional two minutes between analyses. ICP-MS analyses were conducted as previously reported 43 , 44 . Throughout the analysis, CeO + /Ce + was<2.1%.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…During sample analysis sample lines were rinsed to reduce memory effects by washing sequentially with Milli-Q purified water for two minutes and 2% nitric acid for an additional two minutes between analyses. ICP-MS analyses were conducted as previously reported 43 , 44 . Throughout the analysis, CeO + /Ce + was<2.1%.…”
Section: Methodsmentioning
confidence: 99%
“…Calculated solution concentrations obtained from 140 Ce and 142 Ce varied by less than 3.1% on average. [Ce] quantification was obtained using a 7-point external calibration curve spiked with known quantities of Ce in a linear range from 0.050 ng g −1 to 100 ng g −1 43 , 44 . Known aliquots of Ce spikes were analyzed as unknowns to determine external precision as 2.7%.…”
Section: Methodsmentioning
confidence: 99%
“…Folate concentrations were measured using a commercial kit, ID-Vit Folic acid (Immundiagnostic-ALPCO; Salem, NH) [ 54 ]. Metal concentrations were measured as nanograms per gram ( ng / g ) using solution-based inductively coupled plasma mass spectrometry (ICP-MS) methods previously described [ 55 57 ]. All standards, including aliquots of the certified NIST 955c, and procedural blanks were prepared by the same process.…”
Section: Methodsmentioning
confidence: 99%
“…For the first 310 participants, one aliquot was used to measure Cd using established solution-based inductively coupled plasma mass spectrometry (ICP-MS) methods that have been previously described ( Darrah et al. 2009 ; McLaughlin et al. 2011 ; Vidal et al.…”
Section: Methodsmentioning
confidence: 99%