2014
DOI: 10.1016/j.knee.2013.09.006
|View full text |Cite|
|
Sign up to set email alerts
|

Pain evaluation after all-inside anterior cruciate ligament reconstruction and short term functional results of a prospective randomized study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
104
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(109 citation statements)
references
References 16 publications
3
104
0
2
Order By: Relevance
“…FTDs have been extensively tested in vivo 4,5,22,26,33 and ex vivo in isolated device setups, 1,11,20,27,30 as well as in porcine knee ACL reconstructions. 11,24,25,27,28,30,37,38 Petre et al 30 implemented an isolated device testing protocol with the same preload and cyclic loading limits and similar travel velocity.…”
Section: Discussionmentioning
confidence: 99%
“…FTDs have been extensively tested in vivo 4,5,22,26,33 and ex vivo in isolated device setups, 1,11,20,27,30 as well as in porcine knee ACL reconstructions. 11,24,25,27,28,30,37,38 Petre et al 30 implemented an isolated device testing protocol with the same preload and cyclic loading limits and similar travel velocity.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, there is emerging evidence that use of sockets may result in less postoperative pain than the use of tunnels. 20,21 The use of adjustable-loop cortical suspensory fixation devices allows accurate in situ tensioning of the graft, with recent Level III evidence supporting no difference in failure rate or knee stability at 2 years' follow-up versus fixed-loop cortical suspension. 22 The technique also obviates the need for hyperflexion of the knee, which carries the risk of iatrogenic cartilage injury during femoral drilling, among others.…”
Section: Discussionmentioning
confidence: 99%
“…One study (3), clearly mentioning the method for randomization, appropriate blinding, and the withdrawal of patients from follow-up, scored ve points. Two studies (12,14) scored 3 points with all randomization, blinding, and withdrawals documented; however, the detailed method of randomization and blinding was not mentioned. Two studies (9,15) that only mentioned the randomization and withdrawals scored 2 points.…”
Section: Study Selection and Critical Appraisalmentioning
confidence: 99%
“…In autologous graft selection, six studies (3,14,(16)(17)(18)(19) used quadrupled semitendinosus tendon (ST4) in the all-inside group and double gracilis and semitendinosus tendon (DGST) in the full tibial tunnel group; one study did not clearly mention the autologous tendon graft donor site (15). All the studies mentioned the suspensory cortical button graft xation device was used on both the femoral and tibial side in the allinside group of patients.…”
Section: Graft Harvest and Xation Devicementioning
confidence: 99%