1995
DOI: 10.1002/3527605983
|View full text |Cite
|
Sign up to set email alerts
|

Packed Towers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
60
0
2

Year Published

1999
1999
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 120 publications
(65 citation statements)
references
References 0 publications
2
60
0
2
Order By: Relevance
“…-A combined power cycle operating on locally produced gas comprising o 8 Siemens SGT-800 gas turbine generator sets each feeding a heat recovery steam generator (4 identical blocks each block containing 2 gas turbines, 2 heat recovery steam generators (HRSG) and 1 steam turbine) as depicted in Figure 2 o A steam cycle with 4 back pressure steam turbine generator sets and 1 common condensing steam turbine (CCS version) 1 Natural gas combined cycle equipped with capture and storage of CO2.…”
Section: The Plant Featuresmentioning
confidence: 99%
“…-A combined power cycle operating on locally produced gas comprising o 8 Siemens SGT-800 gas turbine generator sets each feeding a heat recovery steam generator (4 identical blocks each block containing 2 gas turbines, 2 heat recovery steam generators (HRSG) and 1 steam turbine) as depicted in Figure 2 o A steam cycle with 4 back pressure steam turbine generator sets and 1 common condensing steam turbine (CCS version) 1 Natural gas combined cycle equipped with capture and storage of CO2.…”
Section: The Plant Featuresmentioning
confidence: 99%
“…A change of ±40% in the effective area induces changes from 1.5% to 3.2% in the CO 2 molar fraction value at the absorber outlet. From our experience and from the discrepancies observed in the literature from one source to another, an uncertainty between ±10% and more certainly of ±20% in the effective area determination is typical (see previously cited sources and Billet, 1995). This means that, to make sure the required performance is achieved, one must Sensitivity of the CO 2 capture cost toward economic parameters.…”
Section: Process Simulations and Economic Evaluationmentioning
confidence: 99%
“…The latter varied over a range from 1 to 7 around a reference value deduced from the correlation developed in Billet (1995) for similar random packing. For all tested values, the CO 2 molar fraction at the absorber outlet happens to vary only very little, from 2.2 to 2.3%.…”
Section: Mass Transfer Parameters Sensitivity Analysismentioning
confidence: 99%
See 2 more Smart Citations