2004
DOI: 10.1016/j.jct.2003.09.006
|View full text |Cite
|
Sign up to set email alerts
|

(p,Vm,T,x) measurements for aqueous LiNO3 solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2004
2004
2006
2006

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 14 publications
0
11
0
Order By: Relevance
“…As shown by various authors (see for example, Refs. [32,[57][58][59][60][61][62][63][64][65]) for aqueous electrolyte solutions the partial molar volume goes also through maximum within the same temperature range. Our earlier PVTx and partial molar measurements [32] for aqueous Na 2 SO 4 showed that the partial molar volume goes through maximum at a temperature of 323 K. Therefore, indirect studies of the volumetric properties of aqueous Na 2 SO 4 also confirmed the maximum in temperature dependence of the B-coefficient.…”
Section: Resultsmentioning
confidence: 99%
“…As shown by various authors (see for example, Refs. [32,[57][58][59][60][61][62][63][64][65]) for aqueous electrolyte solutions the partial molar volume goes also through maximum within the same temperature range. Our earlier PVTx and partial molar measurements [32] for aqueous Na 2 SO 4 showed that the partial molar volume goes through maximum at a temperature of 323 K. Therefore, indirect studies of the volumetric properties of aqueous Na 2 SO 4 also confirmed the maximum in temperature dependence of the B-coefficient.…”
Section: Resultsmentioning
confidence: 99%
“…The apparatus and experimental procedure, described previously by Abdulagatov and Azizov [14][15][16][17][18][19][20][21], Azizov and Akhundov [22][23][24], and Azizov et al [25], was used without modification. Only a brief discussion will be given here.…”
Section: Density Measurementsmentioning
confidence: 99%
“…As has been shown by various authors (see, for example, Refs. [86][87][88][89][90][91][92][93][94] for aqueous electrolyte solutions, the partial molar volumē V also goes through a maximum within the same temperature range. Our earlier PVTx and partial molar volume measurements [58] for K 2 SO 4 (aq) showed that the partial molar volume goes through a maximum at a temperature of about 323 K. Therefore, indirect studies of the volumetric properties of K 2 SO 4 (aq) confirmed the presence of a maximum in the temperature dependence of the B-coefficient.…”
Section: Viscositymentioning
confidence: 99%