2008
DOI: 10.1016/j.exer.2007.12.010
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen saturation levels in the juxta-papillary retina in eyes with glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(33 citation statements)
references
References 21 publications
0
32
0
Order By: Relevance
“…29 More recently, the Fourier transform spectral retinal imaging system was used to compare the OS of the retinal tissues and blood vessels around the optic disc in normal eyes, and eyes with open-angle glaucoma. 30 Overall, 15 eyes with low-tension glaucoma and 41 eyes with hightension glaucoma were compared with 20 normal eyes. The average OS of the juxtapapillary retinal tissues in eyes with normal-tension glaucoma (78 ± 8%) and high-tension glaucoma (82 ± 10%) were reported to be significantly lower than in normal eyes (88 ± 8%; P ¼ 0.002 and P ¼ 0.039, respectively).…”
Section: Principles Of Retinal Oximetrymentioning
confidence: 99%
“…29 More recently, the Fourier transform spectral retinal imaging system was used to compare the OS of the retinal tissues and blood vessels around the optic disc in normal eyes, and eyes with open-angle glaucoma. 30 Overall, 15 eyes with low-tension glaucoma and 41 eyes with hightension glaucoma were compared with 20 normal eyes. The average OS of the juxtapapillary retinal tissues in eyes with normal-tension glaucoma (78 ± 8%) and high-tension glaucoma (82 ± 10%) were reported to be significantly lower than in normal eyes (88 ± 8%; P ¼ 0.002 and P ¼ 0.039, respectively).…”
Section: Principles Of Retinal Oximetrymentioning
confidence: 99%
“…Studies using various retinal oximetry devices to measure the oxygen saturation of the retinal vasculature in glaucoma have been reported. [12][13][14][15][16][17][18][19][20] Hyperspectral imaging combines spectroscopy with digital imaging whereby spectral data (using numerous contiguous wavelengths of light) are obtained in every pixel of an image plane. An oximetry study of the retinal vascular network using a hyperspectral imaging system (images acquired using more than three contiguous wavelengths) in glaucoma has not yet been reported.…”
Section: Introductionmentioning
confidence: 99%
“…Information on this instrument was described in detail previously. 9,10 The retinal cube system consists of an SD-200 optical head, which uses a Sagnac interferometer (ASI Co.) mounted on top of a fundus camera (TRC-50IA, Topcon Co., Tokyo, Japan) and software with acquisition and analysis modules. This system allows measurement of a spectrum in each pixel of the fundus image.…”
Section: Oxygen Saturation Measured By Spectral Retinal Imagingmentioning
confidence: 99%
“…Recently, technological developments have enabled us to measure oxygen saturation levels in the fundus with a 35°c amera. 9,10 This technology can be used to study oxygen levels in retinochoroidal vasculature in a wide variety of diseases and may allow us to investigate clinically the pathophysiologic features of the eye from a new perspective. The aim of this study was to investigate the functional effects of PDT on the retina-choroid, such as macular oxygen saturation and electrophysiological function, using Fourier transform-based spectral retinal imaging (SRI), Heidelberg retinal flowmeter (HRF), and multifocal electroretinogram (mfERG).…”
mentioning
confidence: 99%