2013
DOI: 10.5650/jos.62.989
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen Content and Oxidation in Frying Oil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
31
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 26 publications
(32 citation statements)
references
References 15 publications
0
31
0
1
Order By: Relevance
“…Once oxidation begins, some oxygen in the oil is consumed for the formation of peroxides, which are the primary oxidation products. The oxygen content in oil is a balance of oxygen being absorbed from air and that consumed for oxidation 10 . In the present study, oxygen content and specific gravity of canola oil and PDMS were measured at room temperature to determine the influence of oxygen penetration into oil on those specific gravities.…”
Section: Experimental Designmentioning
confidence: 99%
See 1 more Smart Citation
“…Once oxidation begins, some oxygen in the oil is consumed for the formation of peroxides, which are the primary oxidation products. The oxygen content in oil is a balance of oxygen being absorbed from air and that consumed for oxidation 10 . In the present study, oxygen content and specific gravity of canola oil and PDMS were measured at room temperature to determine the influence of oxygen penetration into oil on those specific gravities.…”
Section: Experimental Designmentioning
confidence: 99%
“…The second method employed a DO/O 2 /Temp Meter, UC-12-SOL, Central Science, Tokyo, Japan, equipped with a polarographic electrode 10 . The oxygen content reading relative oxygen content of canola oil saturated with oxygen by bubbling air at 25 was set as 100 .…”
Section: Determination Of Oxygen Contentmentioning
confidence: 99%
“…Fatty acid composition of blended oil was 0.1 myristic acid, 8.5 palmitic acid, 0.1 palmitoleic acid, 3.5 stearic acid, 35. 4 oleic acid, 41.3 linoleic acid, 7.0 α-linolenic acid, 4.1 others by gas chromatography 11 .…”
Section: Experimental 21 Materialsmentioning
confidence: 99%
“…The oxygen content of oil was determined by a DO/O 2 / Temp Meter UC-12-SOL; Central Science, Tokyo, Japan equipped with a polarographic electrode 11,15 . The oxygen content reading relative oxygen content of blended oil saturated with oxygen by bubbling air at 25 was set as 100 .…”
Section: Relative Oxygen Content Determinationmentioning
confidence: 99%
See 1 more Smart Citation