1999
DOI: 10.1002/(sici)1097-0223(199902)19:2<179::aid-pd473>3.0.co;2-1
|View full text |Cite
|
Sign up to set email alerts
|

Overwhelming maternal cell contamination in amniotic fluid samples from patients with oligohydramnios can lead to false prenatal interphase FISH results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1999
1999
2003
2003

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…However, this should only be necessary where any of the translocation breakpoints are very distal, such the t(19;22)(q13.4;q13.3) in cases 2 and 11 (Table I). As with all interphase FISH analyses, maternal cell contamination may lead to difficulties in interpretation, so should be considered when faced with apparent mosaicism or discordant signal patterns [Ward et al, 1993; Estabrooks et al, 1999].…”
Section: Discussionmentioning
confidence: 99%
“…However, this should only be necessary where any of the translocation breakpoints are very distal, such the t(19;22)(q13.4;q13.3) in cases 2 and 11 (Table I). As with all interphase FISH analyses, maternal cell contamination may lead to difficulties in interpretation, so should be considered when faced with apparent mosaicism or discordant signal patterns [Ward et al, 1993; Estabrooks et al, 1999].…”
Section: Discussionmentioning
confidence: 99%
“…A full karyotype also has the advantage of identifying other chromosomal aneusomies not tested for by the interphase FISH analysis. As with all interphase FISH analyses, maternal cell contamination may lead to dif®culties in interpretation, so should be considered when faced with apparent mosaicism or discordant signal patterns (Ward et al, 1993;Estabrooks et al, 1999). Nevertheless, the use of interphase FISH analysis on prenatal samples from translocation carrier parents allows rapid exclusion of unbalanced segregants that present the highest risk of abnormal offspring.…”
Section: Discussionmentioning
confidence: 99%
“…According to the Vysis company 99.9 per cent of analysable aberrations can be detected (www.Vysis.com). Apart from four cases of sex-discrepancy results, because of maternal cell contamination in oligohydramnios (Estabrooks et al, 1999), up to now no false-positive or false-negative findings for the analysable chromosomal aberrations have been reported with this system in a large study (Eiben et al, 1998a). Because prenatal diagnosis is a highly sensitive field high diagnostic reliability is expected.…”
Section: False-negative Finding In Rapid Interphase Fish Analysis Of mentioning
confidence: 99%