1994
DOI: 10.1016/0960-1481(94)90441-3
|View full text |Cite
|
Sign up to set email alerts
|

Overview of wind/diesel systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0
1

Year Published

1994
1994
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(17 citation statements)
references
References 2 publications
0
16
0
1
Order By: Relevance
“…Other studies have also concluded that typically diesel gen sets have a high economic and environmental cost (Katiraei & Abbey, 2007;Kim & Leng, 1999;Lautier et al, 2007;Lipman, 1994). A common design flaw for diesel based electricity systems in off-grid communities are its excess installed capacity (Schofield, 2011;Weis & Ilinca, 2010).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Other studies have also concluded that typically diesel gen sets have a high economic and environmental cost (Katiraei & Abbey, 2007;Kim & Leng, 1999;Lautier et al, 2007;Lipman, 1994). A common design flaw for diesel based electricity systems in off-grid communities are its excess installed capacity (Schofield, 2011;Weis & Ilinca, 2010).…”
Section: Discussionmentioning
confidence: 99%
“…The large diesel gen sets are sized to meet the maximum peak load plus some regulatory requirement (Lipman, 1994). In the case of Brochet, the peak load was almost twice the average load, however, in some communities it can be as high as five to ten times the average load (Lipman, 1994). And, like in the case of Brochet, the peak values usually occur for a small fractions of the total year (Pelland et al, 2012).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, typical remote power system designs tend to favor a centralized power plant architecture with oversized and redundant generation units. In most cases, some sort of "energy storage" is used to perform voltage and frequency regulation and maintain sufficient generation reserve, [8], [9]. These approaches are very costly and may not be applicable for outage management on rural feeders for two reasons: (1) the system operates in connection to the main grid most of the time and may become an island only a few times per year, (2) multiple DG units may be some distance apart which requires distributed control and advanced power management strategies.…”
Section: B Hydro Quebec Planned Islandingmentioning
confidence: 99%
“…Two types of powergeneration components have been considered: (1) WTs with 20 kW rated power and (2) CDGs with 15 kW rated power. The number of CDGs is kept constant and equal to one, as multiple-diesel strategies are normally applied in much larger isolated systems [17], whereas the number of WTs can vary from one to three. The evaluation of each examined system is 13.…”
Section: Reliability and Performance Evaluation Of Sipsmentioning
confidence: 99%