Abstract: The high-performance ‎liquid chromatography-mass ‎spectrometry (LC-MS) ‎technique is widely applied ‎to ‎routine analysis in many ‎matrices. Despite the ‎enormous application of ‎LC/MS, this technique is ‎subjected to ‎drawbacks ‎called matrix...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 68 publications
(31 citation statements)
references
References 111 publications
0
27
0
Order By: Relevance
“…Recovery and matrix effects were assessed by a postextraction addition approach at low, medium, and high QC levels by using 6 lots of blank samples. 11 The IS-normalized matrix factor (IS-norm MF) was calculated by dividing the MF of gilteritinib by the MF of the IS. The CV% of the IS-norm MF calculated from the 6 lots should be <15%.…”
Section: Methodsmentioning
confidence: 99%
“…Recovery and matrix effects were assessed by a postextraction addition approach at low, medium, and high QC levels by using 6 lots of blank samples. 11 The IS-normalized matrix factor (IS-norm MF) was calculated by dividing the MF of gilteritinib by the MF of the IS. The CV% of the IS-norm MF calculated from the 6 lots should be <15%.…”
Section: Methodsmentioning
confidence: 99%
“…21 Electrospray ionization (ESI) is the most used interface in today's LC-MS hardware. 21 However, it shows higher susceptibility with respect to other atmospheric pressure ionization (API) sources. 21,22 To assess the order of the matrix effect, postcolumn infusion and post-extraction addition are the methods of choice, with the latter being widely used for method validation and for this study.…”
Section: Introductionmentioning
confidence: 99%
“…21 However, it shows higher susceptibility with respect to other atmospheric pressure ionization (API) sources. 21,22 To assess the order of the matrix effect, postcolumn infusion and post-extraction addition are the methods of choice, with the latter being widely used for method validation and for this study. 21,22 In addition to this, there is also the possibility of solvent dilution and minimizing the injection volume to reduce the matrix effect.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The multiple reaction monitoring approaches can well eliminate intruders and make the analysis easier. 2 …”
Section: Introductionmentioning
confidence: 99%