Overivew of grid codes for photovoltaic integration

Abstract: Abstract-The increasing grid-connected photovoltaic (PV) power stations might threaten the safety and stability of power system. Therefore, the grid code is developed for PV power stations to ensure the security of PV integrated power systems. In this paper, requirements for PV power integration in different grid codes are first investigated. On this basis, the future advocacy is concluded. Finally, several evaluation indices are proposed to quantify the grid code compliance so that the system operators can va… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 3 publications
(3 reference statements)
0
12
0
Order By: Relevance
“…Active and reactive power control systems mainly depend on the change of the control signal of the two converters of the system. Based on some European countries grid code and Chinese grid code for integrating the PV to the grid, the following requirements should be applied [22,23]:…”
Section: Photovoltaic Parkmentioning
confidence: 99%
“…Active and reactive power control systems mainly depend on the change of the control signal of the two converters of the system. Based on some European countries grid code and Chinese grid code for integrating the PV to the grid, the following requirements should be applied [22,23]:…”
Section: Photovoltaic Parkmentioning
confidence: 99%
“…The summation of output voltage produced by each panel in the string must exist within the allowable per unit voltage range as determine by the North Amer-ican Electric Reliability Corporation (NERC). The standards described by NERC regarding the allowable range for the string voltage of grid connected PV is 0.90 to 1.10 per unit voltage [42]. Chapter 5…”
Section: Output Voltage Comparisonsmentioning
confidence: 99%
“…Solar energy grid connection codes may be issued as national standards in various countries or by transmission and distribution system operators [22]. These solar energy grid connection codes may be included in the relevant codes or issued separately as a complementary part.…”
Section: Comparison Of Solar Energy Grid Connection Codesmentioning
confidence: 99%
“…Comparisons of some rules in PV grid connection codes of Germany [1,3,22], the UK [1,22], [24][25][26][27], the USA [28][29][30][31][32], and Egypt [7][8][9][10][11], [33] are presented here. The comparisons include power and frequency control rules and reactive power control rules.…”
Section: Requirement Of Reactive Current Injection During the Fault (mentioning
confidence: 99%