1978
DOI: 10.1136/hrt.40.2.106
|View full text |Cite
|
Sign up to set email alerts
|

Overdrive suppression of implanted pacemakers in patients with AV block.

Abstract: Patients being permanently paced for symptomatic AV block were studied by overdrive suppression of the QRS-inhibited pacemaker, in order to observe the underlying heart rhythm. The chest wall stimulation method was used. In complete AV block the escape rhythm recovery time proved highly reproducible on repeated testing on the same day, and in many patients remained so over months or years. Occasionally, a doubling of the escape rhythm recovery time was seen, suggesting initial exit block of the escape focus. R… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
4
0

Year Published

1979
1979
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 8 publications
(6 reference statements)
1
4
0
Order By: Relevance
“…In our study, PM dependency was found in 43.5% of the cases, similar to what has been reported in the human literature, where the time of onset is approximately 3 years …”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…In our study, PM dependency was found in 43.5% of the cases, similar to what has been reported in the human literature, where the time of onset is approximately 3 years …”
Section: Discussionsupporting
confidence: 91%
“…[45][46][47] In our study, PM dependency was found in 43.5% of the cases, similar to what has been reported in the human literature, where the time of onset is approximately 3 years. 24,26,48 Limitations of this study include its retrospective nature, which influenced particularly the timing of re-evaluation: T1 and T2 were homogeneous whereas T3 and T4 had wider CI. Intrinsic rhythm was evaluated during a limited time frame, and for this reason paroxysmal AVB could not be completely ruled out.…”
Section: Discussionmentioning
confidence: 99%
“…5, November-December, 1982) pacemaker dependence, underlying heart rhythm, spontaneous heart rhythm, chest wall stimulation, sick sinus syndrome, atrioventricular block During long-term follow-up a substantial number of paced patients show spontaneous cardiac activity faster than the basic rate of their pulse generators. However, in approximately 40 percent of patients' requiring permanent cardiac pacemakers because of symptomatic bradyarrhythmias, continuous pacemaker-induced rhythm obscures the intrinsic cardiac activity at consecutive follow-up examinations.Overdrive suppression of QRS-inhibited pacemakers by chest wall stimulation>" permits pacing to be stopped briefly and safely, [2][3][4][5]7,8,11 This easily applicable and non-invasive technique enables the clinician or investigator to evaluate the underlying cardiac rhythm.…”
mentioning
confidence: 99%
“…Overdrive suppression of QRS-inhibited pacemakers by chest wall stimulation>" permits pacing to be stopped briefly and safely, [2][3][4][5]7,8,11 This easily applicable and non-invasive technique enables the clinician or investigator to evaluate the underlying cardiac rhythm.…”
mentioning
confidence: 99%
“…1). In patients without bradycardia episodes the mean observation time was 5.4 (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16) months.…”
Section: Follow-upmentioning