2016
DOI: 10.4103/0019-5049.193704
|View full text |Cite|
|
Sign up to set email alerts
|

Overcoming airway challenges with the C-MAC® video laryngoscope in a child with Goldenhar syndrome

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 4 publications
(4 reference statements)
0
5
0
Order By: Relevance
“…The sample size was calculated on the basis of results of the pilot study done on 10 infants using sample size calculator. The mean (SD) of time to intubation in Miller group was 33 seconds and in CMAC as 27 seconds in lateral position. Therefore, to detect a difference of 6 seconds, with level of significance at 5%, we required the sample size of 27 patients at 80% power.…”
Section: Methodsmentioning
confidence: 98%
See 2 more Smart Citations
“…The sample size was calculated on the basis of results of the pilot study done on 10 infants using sample size calculator. The mean (SD) of time to intubation in Miller group was 33 seconds and in CMAC as 27 seconds in lateral position. Therefore, to detect a difference of 6 seconds, with level of significance at 5%, we required the sample size of 27 patients at 80% power.…”
Section: Methodsmentioning
confidence: 98%
“…The mean (SD) of time to intubation in Miller group was 33 seconds and in CMAC as 27 seconds in lateral position. Therefore, to detect a difference of 6 seconds, with level of significance at 5%, we required the sample size of 27 patients at 80% power. Although this difference might not be of clinical significance in supine position, but we assumed an approximately 20% difference clinically relevant in lateral position owing to the positional difficulty in performing tracheal intubation in lateral position and poor oxygen reserve in the study population.…”
Section: Methodsmentioning
confidence: 98%
See 1 more Smart Citation
“…C-MAC video laryngoscope has also been used for these patients. [ 3 ] Although the use of video laryngoscope and fibreoptic intubation has been described, it can be difficult and is associated with high failure rates. [ 4 ] Computer-generated virtual imaging of the airway can generate video output similar to the views obtained from a fibrescope and may be useful in these cases.…”
mentioning
confidence: 99%
“…60 of Indian Journal of Anaesthesia[1], the name of the third author is written incorrectly as “Chong Eu Soon” instead of “Chong Soon Eu” in the author names section.…”
mentioning