2019
DOI: 10.3390/buildings9100209
|View full text |Cite
|
Sign up to set email alerts
|

Outdoor Test Cell Modelling with Modelica

Abstract: The experimental setup implements a simplified PASSYS test cell construction, which is combined with a detailed simulation to reduce measurement effort. To analyze the cell’s dynamic behavior, the test cell was closely monitored with thermal sensors, and different static and dynamic heating modes were applied during a three-week calibration period. Co-heating tests were performed for steady-state measurements and cyclic heating periods account for the transient behavior of the test cell. The cells response was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…Other than the ventilated DSFs evaluated in previous research [8,10,11], the SEBF is not actively ventilated or used for active energy production, e.g., for hot water or room heating. An accurate transient heat flow model of the façade element shall be developed and validated by comparison against measurements on a test cell [12]. The effect of solar energy use and solar thermal storage are evaluated by annual simulations under the climatic conditions of four locations in Europe.…”
Section: Objectivesmentioning
confidence: 99%
See 4 more Smart Citations
“…Other than the ventilated DSFs evaluated in previous research [8,10,11], the SEBF is not actively ventilated or used for active energy production, e.g., for hot water or room heating. An accurate transient heat flow model of the façade element shall be developed and validated by comparison against measurements on a test cell [12]. The effect of solar energy use and solar thermal storage are evaluated by annual simulations under the climatic conditions of four locations in Europe.…”
Section: Objectivesmentioning
confidence: 99%
“…The performance of the SEBF with and without thermal storage (SEBF w and SEBF a ) was evaluated assuming an attached test cell [12]. The cell's south-facing wall was completely replaced by a side-by-side installation of either two SEBF water or two SEBF air elements.…”
Section: Simulation-based Performance Assessmentmentioning
confidence: 99%
See 3 more Smart Citations