Outcompeting GC for the detection of legacy chlorinated pesticides: online-SPE UPLC APCI/MSMS detection of endosulfans at part per trillion levels

Abstract: Endosulfan, the last remaining organochlorine pesticide, has been the subject of a number of international regulations and restriction/banning action plans worldwide. Occurrence of endosulfan residues in South Florida environments has been widely described in the literature for more than two decades. This work describes a selective, sensitive, and fast online solid-phase extraction (SPE) method coupled with liquid chromatography separation and tandem mass spectrometry (LC-MS/MS) for the determination of endosu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
17
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 23 publications
0
17
0
Order By: Relevance
“…Preliminary tests on sucralose standards through direct injection into the LC/MS/MS were performed using HESI and APCI sources. The APCI source showed better sensitivity than HESI, moreover ESI and/or HESI spectrum generally contains abundant and extensive series of adducts ions with methanol and inorganic ions [24,38]. The APCI source was then selected and carefully optimized to produce reproducible spectra of the target compound.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Preliminary tests on sucralose standards through direct injection into the LC/MS/MS were performed using HESI and APCI sources. The APCI source showed better sensitivity than HESI, moreover ESI and/or HESI spectrum generally contains abundant and extensive series of adducts ions with methanol and inorganic ions [24,38]. The APCI source was then selected and carefully optimized to produce reproducible spectra of the target compound.…”
Section: Methodsmentioning
confidence: 99%
“…The ionization process associated with APCI is one of the most efficient, being considered more energetic or less soft than ESI, where gas phase reactions leading to the loss of net charge on the analyte may generate more fragment ions relative to the parent ion [28]. In fact, for certain classes of compounds that are traditionally very difficult to ionize or tend to show low sensitivity in LC-MS/MS techniques, electron capture negative APCI has provided increased sensitivity for these ‘tough to ionize’ compounds [24,29]. APCI has been reported to be more sensitive than ESI for triazines, phenylurea herbicides and organochlorine pesticides [24,30,31].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Suppressive effects of formic acid were also observed for the analysis of other compounds such as endosulfan (Quinete et al, 2013). Therefore formic acid was eliminated and the mobile phase was switched to acetonitrile and water resulting in a 20-fold increase in sensitivity.…”
Section: Methods Developmentmentioning
confidence: 99%
“…More recently, studies employing liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) have been published for the analysis of sucralose in water samples by direct injection (higher detection limits) or offline SPE (Loos et al, 2009b;Scheurer et al, 2009b;Ferrer and Thurman, 2010a;Mawhinney et al, 2011b;Minten et al, 2011b;Ordonez et al, 2012a). Nowadays the use of online SPE has shown important improvements such as higher sensitivity, analysis of smaller sample volumes, limited sample loss, no carry-over and robust and reproducible detection, while increasing sample throughput (Neset et al, 2010;Heeb et al, 2012;Panditi et al, 2013;Quinete et al, 2013).…”
Section: Introductionmentioning
confidence: 99%