2021
DOI: 10.1111/jocs.15766
|View full text |Cite
|
Sign up to set email alerts
|

Outcomes of long versus short stent cronus hybrid prosthesis in type A aortic dissection: A single centre experience

Abstract: Objectives The frozen elephant trunk (FET) technique has become an important tool in the treatment of acute type A aortic dissection. The aim of this study was to evaluate the effect of long FET on spinal cord injury (SCI) and distal aortic remodeling after acute type A aortic dissection based on clinical and radiological outcomes. Methods From January 2018 to November 2019, 158 patients (mean age 51.8 years [range: 32–78 years], 88.6% male) with acute type A aortic dissection were treated by FET with 100 mm (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 21 publications
(55 reference statements)
0
3
0
Order By: Relevance
“…A total of 79,931 records were collected via online database review, out of which 7345 studies were eligible for abstract screening. After applying the exclusion criteria, 109 records were adopted for full‐text screening, and eventually, reported data of 43 studies including 5068 patients who underwent TAR with FET were reviewed 4,15–56 (Figure 1).…”
Section: Resultsmentioning
confidence: 99%
“…A total of 79,931 records were collected via online database review, out of which 7345 studies were eligible for abstract screening. After applying the exclusion criteria, 109 records were adopted for full‐text screening, and eventually, reported data of 43 studies including 5068 patients who underwent TAR with FET were reviewed 4,15–56 (Figure 1).…”
Section: Resultsmentioning
confidence: 99%
“…A recent metanalysis showed that the pooled prevalence of paraplegia was 3.5% 2 . Wang et al 3 reported an incidence of SCD of 4.4% in 158 patients with ATAAD. They have implanted longer (150 mm) Cronus hybrid prosthesis (HP) in patients who are taller than 160 cm and they found there was no statistical difference between the long and short (100 mm) HP in regards to SCD.…”
mentioning
confidence: 99%
“…The average height of the Asian male (166–174 cm) is approximately 7–8 cm shorter than the European population (179–182 cm) 5 . Wang et al 3 have used 150 mm Cronus HP in 45 patients with height great than 160 cm tall and reported SCD in one patient (2.2%). Theoretically, this is equivalent to using 150 mm HP in average European men who are 180 cm tall.…”