Outcomes after aortic graft-to-graft anastomosis with an automated circular stapler: A novel approach

Abstract: Use of an end-to-end anastomotic automated circular stapler is safe, effective, and durable in performing graft-to-graft anastomoses during complex thoracic aortic surgery. Further evaluation and refinement of this technique are warranted.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 15 publications
(22 reference statements)
0
3
0
Order By: Relevance
“…Since their invention, surgical staplers have been routinely used in pulmonary and gastrointestinal procedures. However, there are few studies in which circular stapling devices, such as the Intraluminal Stapler System 18 (Ethicon, Somerville, NJ) and the EEA Stapler 19 (Covidien, Mansfield, Mass), have been used in aortic surgery. To form the anastomosis, the anvil is tied into one end of the aorta with a polypropylene purse-string suture.…”
Section: Aad Typesmentioning
confidence: 99%
See 1 more Smart Citation
“…Since their invention, surgical staplers have been routinely used in pulmonary and gastrointestinal procedures. However, there are few studies in which circular stapling devices, such as the Intraluminal Stapler System 18 (Ethicon, Somerville, NJ) and the EEA Stapler 19 (Covidien, Mansfield, Mass), have been used in aortic surgery. To form the anastomosis, the anvil is tied into one end of the aorta with a polypropylene purse-string suture.…”
Section: Aad Typesmentioning
confidence: 99%
“…A total of 41 studies 10,11,13,14,[16][17][18][19] were identified that reported outcomes for the use of AADs during surgery for thoracic and abdominal aortic reconstruction (Supplementary Tables I and II, online only). The meta-analysis included 27 studies with 50 cohorts, incorporating 1260 patients (Supplementary Table I, online only).…”
Section: Description Of Studiesmentioning
confidence: 99%
“…Currently, cardiothoracic surgery cases that require vascular anastomoses are performed using a hand-sewn technique. Some of the literature has evaluated the possibility of using a circular end-to-end anastomosis stapler for prosthetic graft to graft anastomoses, 1 but that still remains rarely used and was not described for primary vascular anastomoses.…”
mentioning
confidence: 99%