Outbreak of Legionnaires' disease on a cruise ship linked to spa-bath filter stones contaminated with Legionella pneumophila serogroup 5

Abstract: In January 2003, two cases of Legionnaires' disease associated with a ship's cruise were registered in the database of National Epidemiological Surveillance of Infectious Diseases. A 70-year-old male heavy smoker with mild emphysema contracted the disease during a cruise. Legionella pneumophila serogroup (sg) 5 was isolated from the patient's sputum and the ship's indoor spa. The isolate from the spa matched the patient's isolate by genotyping performed by pulsed-field gel electrophoresis (PFGE). The second ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
30
0
2

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(34 citation statements)
references
References 14 publications
(20 reference statements)
2
30
0
2
Order By: Relevance
“…The number of bacteria in film droplets can be 20-fold higher than that in the bulk water (34). The presence of high numbers of L. pneumophila organisms in spa pool water does not always result in infection, and in previous investigations, the absence or low level of illness has been attributed to the absence of air compressors or failure to use the air injection system (7,27). The results of the current investigation support these conclusions.…”
Section: ϫ3supporting
confidence: 81%
See 1 more Smart Citation
“…The number of bacteria in film droplets can be 20-fold higher than that in the bulk water (34). The presence of high numbers of L. pneumophila organisms in spa pool water does not always result in infection, and in previous investigations, the absence or low level of illness has been attributed to the absence of air compressors or failure to use the air injection system (7,27). The results of the current investigation support these conclusions.…”
Section: ϫ3supporting
confidence: 81%
“…However, Legionella spp. have been recovered from public spa pools that have been treated and/or emptied appropriately (11,26,27), implying that the concentration of disinfectant necessary to achieve microbial control may be higher than that normally recommended. Thus, domestic spa pool users may be at risk from Legionella despite complying with manufacturers' maintenance instructions.…”
Section: Discussionmentioning
confidence: 99%
“…Several isolated and clustered cases of legionellosis have been associated with the use of whirlpool spas (Nagai et al 2003;Foster et al 2006;Kura et al 2006;Beyrer et al 2007;Burnsed et al 2007;Yoder et al 2008). To prevent such outbreaks, specific recommendations for spas have been established.…”
Section: Introductionmentioning
confidence: 99%
“…In Japan, more than 900 cases of infection by Legionella species from contaminated artificial whirlpool spas or natural hot springs have emerged in the past decade (Anonymous 2000; Nakamura et al. 2003; Kura et al. 2006); in particular, a major outbreak in 2002 originating from a newly opened hot spring spa involved 295 people, including seven deaths (Okada et al.…”
Section: Introductionmentioning
confidence: 99%