2012 10th International Power &Amp; Energy Conference (IPEC) 2012
DOI: 10.1109/asscc.2012.6523258
|View full text |Cite
|
Sign up to set email alerts
|

Ouput power smoothening of variable-speed wind turbine systems by pitch angle control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…Also, C p is the aerodynamic efficiency of rotor. PMSG voltage equations and other equation of wind turbine are presented in [35,46]. Enhancement of microgrid dynamic responses under fault… Fig.…”
Section: Wind Turbine and Pmsg Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, C p is the aerodynamic efficiency of rotor. PMSG voltage equations and other equation of wind turbine are presented in [35,46]. Enhancement of microgrid dynamic responses under fault… Fig.…”
Section: Wind Turbine and Pmsg Modelingmentioning
confidence: 99%
“…In this paper, the FLC by applying wind speed and active power as inputs is proposed to smooth the output power fluctuations of WT in above rated speed and a comparison of the performances of the FLC with the conventional PI controller. Moreover, another drawback in mentioned papers is that they are not practically connected to grid to investigate the system performance [33][34][35].…”
Section: Introductionmentioning
confidence: 98%
“…The amount of electricity a turbine is able to produce depends on the speed of the rotor and the speed of the wind that propels the rotor [31,38]. Aerodynamic wind power is calculated in following equations.…”
Section: Wind Turbine Modelingmentioning
confidence: 99%
“…As in mentioned items, wind speed's is ignored, the controller have not fast response and may cause mechanical damages to synchronous generator. Further, another problem with these studies is that they are not practically connected to the grid to analyze the system performance [29][30][31].…”
Section: Introductionmentioning
confidence: 99%
“…In [15] active power and in [13,14] both reactive power and rotational rotor speed are used as input signals and because in mentioned items wind speed's been ignored, the controller has not fast response and may cause mechanical damages to synchronous generator. Also, another problem in these articles that it is not practically connected to grid [14][15][16][17][18], but the grid connected mode in this paper is proposed to analyse the system performance. In recent years, many topologies based on power electronic devices with different level of complexity and cost is developed investigated in order to connect a PMSG to network.…”
Section: Introductionmentioning
confidence: 99%