2016
DOI: 10.1002/adhm.201600494
|View full text |Cite
|
Sign up to set email alerts
|

Organic Transistor Arrays Integrated with Finger‐Powered Microfluidics for Multianalyte Saliva Testing

Abstract: A compact multianalyte biosensing platform is reported, composed of an organic electrochemical transistor (OECT) microarray integrated with a pumpless "finger-powered" microfluidic, for quantitative screening of glucose, lactate, and cholesterol levels. A biofunctionalization method is designed, which provides selectivity towards specific metabolites as well as minimization of any background interference. In addition, a simple method is developed to facilitate multi-analyte sensing and avoid electrical crossta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
194
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 173 publications
(195 citation statements)
references
References 43 publications
1
194
0
Order By: Relevance
“…This analysis can provide a direct evidence of any changes occurring in the cell metabolism and uptake of glucose induced by the FSS. Taking advantage of the facile biofunctionalization of PEDOT:PSS 26 , we implemented a glucose electrochemical biosensor based on our OECTs technology 52 . Figure 3c shows the glucose uptake of the cells over time, for samples collected before and after the 15 h of FSS stimulation at 0.3 dyne cm −2 .…”
Section: Results and Discussion Flow Shear Stress Mechanical Stimulationmentioning
confidence: 99%
See 3 more Smart Citations
“…This analysis can provide a direct evidence of any changes occurring in the cell metabolism and uptake of glucose induced by the FSS. Taking advantage of the facile biofunctionalization of PEDOT:PSS 26 , we implemented a glucose electrochemical biosensor based on our OECTs technology 52 . Figure 3c shows the glucose uptake of the cells over time, for samples collected before and after the 15 h of FSS stimulation at 0.3 dyne cm −2 .…”
Section: Results and Discussion Flow Shear Stress Mechanical Stimulationmentioning
confidence: 99%
“…Typically, 100 μL of the exhausted media from the microfluidics was collected (everỹ 1 h) in a Eppendorf tube for 3 h prior and 6 h after application of a physiological relevant fluid shear stress. With regards to the enzymatic functionalization of the OECT, a PEDOT:PSS planar gate electrode (600 × 600 μm 2 ) was modified with glucose oxidase enzyme based on a previously reported method 30 . Briefly, the gate electrode was plasma activated (25 W, 2 min) to favor covalent attachment of a heterobifunctional silane (GOPS) via condensation reaction.…”
Section: Materials and Methods Oect Fabrication And Operationmentioning
confidence: 99%
See 2 more Smart Citations
“…Quantification of the binding of PLL was carried out by fluorescence microscopy as before, along with demonstration of preferential binding to the PLL functionalized areas on the PEDOT:PSS film (Figure 6c 64 Thus, the biofunctionalization strategy is designed to generate more sensitive and specific sensing in complex biological fluids.…”
Section: Silane-mediated Biofunctionalization Of Pedot:pssmentioning
confidence: 99%