Organic Rankine Cycle power generation from industrial waste heat recovery integrated with solar hot water system by using vapor compression heat pump as heating booster in Thailand

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(1 citation statement)
references
References 15 publications
0
1
0
Order By: Relevance
“…where 𝜖 is the effectiveness (dimensionless, set to 0.9 or 90% [113]), (𝑚̇• 𝐶 𝑝 ) min is the lower of the products of heat capacity and mass flow rate in the two fluid flows (W/K), and 𝑇 𝑖𝑛,1 − 𝑇 𝑖𝑛,2 is the difference between inlet temperatures (K). Losses are assumed to be negligible.…”
Section: Heat Exchanger Sub-modelmentioning
confidence: 99%
“…where 𝜖 is the effectiveness (dimensionless, set to 0.9 or 90% [113]), (𝑚̇• 𝐶 𝑝 ) min is the lower of the products of heat capacity and mass flow rate in the two fluid flows (W/K), and 𝑇 𝑖𝑛,1 − 𝑇 𝑖𝑛,2 is the difference between inlet temperatures (K). Losses are assumed to be negligible.…”
Section: Heat Exchanger Sub-modelmentioning