1972
DOI: 10.1021/ac60313a017
|View full text |Cite
|
Sign up to set email alerts
|

Organic elemental analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

1976
1976
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 300 publications
0
9
0
Order By: Relevance
“…TC and total inorganic carbon (TIC) content were measured using a UIC model 5011 CO2 Coulometer, with TOC determined by subtraction of TIC from TC. Total nitrogen (TN) was determined in a Variomax C/N following the Dumas' method (Ma & Gutterson, 1970). BSi was extracted following the alkaline leaching technique (Mortlock & Froelich, 1989), measuring the resulting extract by the molybdate blue colorimetric method (Hansen & Grashoff, 1983) using an AutoAnalyser Technicon II.…”
Section: Methodsmentioning
confidence: 99%
“…TC and total inorganic carbon (TIC) content were measured using a UIC model 5011 CO2 Coulometer, with TOC determined by subtraction of TIC from TC. Total nitrogen (TN) was determined in a Variomax C/N following the Dumas' method (Ma & Gutterson, 1970). BSi was extracted following the alkaline leaching technique (Mortlock & Froelich, 1989), measuring the resulting extract by the molybdate blue colorimetric method (Hansen & Grashoff, 1983) using an AutoAnalyser Technicon II.…”
Section: Methodsmentioning
confidence: 99%
“…Elemental analysis was conducted as C/H/N/S analyses (oxygen was determined indirectly) on an EA 1108 CHNS-O elemental analyzer (CarloErba Instruments, CE Elantech, Inc.). 38 …”
Section: Methodsmentioning
confidence: 99%
“…All samples (3 mg per analysis) were thoroughly dried prior to elemental analysis and stored under an inert atmosphere. Elemental analysis was performed as C/H/N/S (oxygen was determined indirectly) analyses on an EA 1108 CHNS-O (Carlo Erba Instruments, CE Elantech, Inc.) elemental analyzer …”
Section: Methodsmentioning
confidence: 99%
“…Elemental analysis was performed as C/H/N/S (oxygen was determined indirectly) analyses on an EA 1108 CHNS-O (Carlo Erba Instruments, CE Elantech, Inc.) elemental analyzer. 41 Preparation of Lignin Samples for Headspace GC/MS. For the determination of sulfonic acid groups in LS, 5−15 mg of LS was weighed into 10 mL headspace vials.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation