2007
DOI: 10.1118/1.2723885
|View full text |Cite
|
Sign up to set email alerts
|

Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination

Abstract: As multidetector computed tomography (CT) serves as an increasingly frequent diagnostic modality, radiation risks to patients became a greater concern, especially for children due to their inherently higher radiosensitivity to stochastic radiation damage. Current dose evaluation protocols include the computed tomography dose index (CTDI) or point detector measurements using anthropomorphic phantoms that do not sufficiently provide accurate information of the organ-averaged absorbed dose and corresponding effec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
64
0
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(65 citation statements)
references
References 44 publications
0
64
0
1
Order By: Relevance
“…A previously validated multidetector CT source model was created by using Monte Carlo simulation-based techniques (14)(15)(16)(17)(18). The CT scanner modeled was a LightSpeed 16 (GE Medical Systems).…”
Section: Multidetector Ct Source Modelmentioning
confidence: 99%
“…A previously validated multidetector CT source model was created by using Monte Carlo simulation-based techniques (14)(15)(16)(17)(18). The CT scanner modeled was a LightSpeed 16 (GE Medical Systems).…”
Section: Multidetector Ct Source Modelmentioning
confidence: 99%
“…Axelsons et al [15] or Giacco et al [16] used a physical anthropomorphic phantom, while other investigators used Monte Carlo voxelized phantoms [17]. In both methodologies, unlike what happens in the adult, the phantoms are size and age specific [18].…”
Section: Patient Dosementioning
confidence: 99%
“…The dose calculations based on CTDI or DLP are readily available indicators of the radiation dose in CT studies. The organ dose and the effective dose can be estimated from the CTDI or the DLP using conversion factors derived from the Monte Carlo simulation of photon interactions within a simplified mathematical model of the human body 16. Accordingly, new series of Monte Carlo calculations have been carried out at National Radiological Protection Board for a family of 6 geometric mathematical phantoms, representing ages from newborn to adult.…”
Section: Discussionmentioning
confidence: 99%