Orderly Arranged Fluorescence Dyes as a Highly Efficient Chemiluminescence Resonance Energy Transfer Probe for Peroxynitrite

Abstract: Chemiluminescence (CL) probes for reactive oxygen species (ROS) are commonly based on a redox reaction between a CL reagent and ROS, leading to poor selectivity toward a specific ROS. The energy-matching rules in the chemiluminescence resonance energy transfer (CRET) process between a specific ROS donor and a suitable fluorescence dye acceptor is a promising method for the selective detection of ROS. Nevertheless, higher concentrations of fluorescence dyes can lead to the intractable aggregation-caused quenchi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
28
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 52 publications
(31 citation statements)
references
References 46 publications
1
28
0
Order By: Relevance
“…All the negative samples (1-10) are detected to be negative using C-mode GLFT, CMIA and ELISA. For positive samples (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30), sample 26 is detected to be negative by these three methods, and sample 27 is also detected to be negative using ELISA ( Figure S11). However, the sample 27 is correctly detected to be positive using C-mode GLFT and CMIA ( Figure 6).…”
Section: Serum Samples Analysismentioning
confidence: 99%
“…All the negative samples (1-10) are detected to be negative using C-mode GLFT, CMIA and ELISA. For positive samples (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30), sample 26 is detected to be negative by these three methods, and sample 27 is also detected to be negative using ELISA ( Figure S11). However, the sample 27 is correctly detected to be positive using C-mode GLFT and CMIA ( Figure 6).…”
Section: Serum Samples Analysismentioning
confidence: 99%
“…As a result, the fluorescence lifetime and quantum yield of fluorescence dyes would increase when they were assembled on the surface of LDHs. 32,33 The successful improvements of FRET and CRET in the LDH matrix inspirits us to construct an efficient ERET process by layer-by-layer (LBL) electrostatic assembly of CoAl−LDH nanosheets with some ECL molecules (i.e., ERET donors and acceptors). However, the ERET with LDH nanosheets have not been established yet.…”
Section: +mentioning
confidence: 99%
“…Chemiluminescence (CL) has become very popular as an analytical technique in recent years, as they offer significant gains in sensitivity without interference from background light and rapidity at a low cost, both in instrumentation and materials [30][31][32][33]. While, to the best of our knowledge, there was no report about chemiluminescence homogenous immunoassay for the detection of BPA, in this study, we developed a singlet oxygen channeling chemiluminescence homogenous immunoassay for the quantitative determination of BPA in environmental water samples.…”
Section: Introductionmentioning
confidence: 99%