1978
DOI: 10.1063/1.90023
|View full text |Cite
|
Sign up to set email alerts
|

Optoacoustic detection of sulphur dioxide below the parts per billion level

Abstract: We report a novel optoacoustic detection scheme which is suited for use with low-power radiation sources. The improved detection capability is demonstrated for SO2 with a frequency-doubled dye laser of 1 mW uv output power, allowing the detection of SO2 concentrations as low as 0.12 ppb.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0
1

Year Published

1980
1980
2012
2012

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 71 publications
(15 citation statements)
references
References 15 publications
0
14
0
1
Order By: Relevance
“…Opto-acoustic spectroscopy is a variation on the absorption method, relying on the conversion of energy from a resonantly excited atom or molecule to thermal energy in the surrounding material of the sample, with the resulting expansion detected by a pressure-sensitive element -eg, a capacitance microphone. Despite an only moderate sensitivity of around 10'°atoms/cm3 3 (Koch and Lahmann, 1978), the method is important in molecular spectroscopy, where often many nonradiative decay processes make techniques such as fluorescence spectroscopy very difficult.…”
Section: Absorption Methodsmentioning
confidence: 99%
“…Opto-acoustic spectroscopy is a variation on the absorption method, relying on the conversion of energy from a resonantly excited atom or molecule to thermal energy in the surrounding material of the sample, with the resulting expansion detected by a pressure-sensitive element -eg, a capacitance microphone. Despite an only moderate sensitivity of around 10'°atoms/cm3 3 (Koch and Lahmann, 1978), the method is important in molecular spectroscopy, where often many nonradiative decay processes make techniques such as fluorescence spectroscopy very difficult.…”
Section: Absorption Methodsmentioning
confidence: 99%
“…The shape of the PA cell is thus of prime importance and many different designs have been proposed [3 and references therein]. To improve the PA sensor sensitivity acoustically resonant PA [4][5][6][7][8][9][10][11], multipass [12,13], intracavity [14,15] and parallel cells [16] have been developed. Synchronous noise generated by the light absorption at the cell windows is a sensitivity limiting factor that has been minimized by the development of acoustic baffles [17], ''windowless" [18], differential [19,20] and quartz enhanced [21] PA cells.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, PA cells for multipass (Koch & Lahmann, 1978;Nägele & Sigrist, 2000) or intracavity operation (Fung & Lin, 1986;Harren et al, 1990a) were designed. The effect of window heating in the amplitude modulation schemes has been minimized by introducing acoustic baffles (Dewey, 1977), developing windowless cells (Gerlach & Amer, 1980;Miklos & Lörincz, 1989;Angeli et al, 1992), or using tunable air columns (Bijnen et al, 1996).…”
Section: Photoacoustic Cellmentioning
confidence: 99%