2009
DOI: 10.1108/03321640910929281
|View full text |Cite
|
Sign up to set email alerts
|

Optimum regulation of DC sources in cascaded multi‐level inverters

Abstract: If you would like to write for this, or any other Emerald publication, then please use our Emerald for Authors service information about how to choose which publication to write for and submission guidelines are available for all. Please visit www.emeraldinsight.com/authors for more information. About Emerald www.emeraldinsight.comEmerald is a global publisher linking research and practice to the benefit of society. The company manages a portfolio of more than 290 journals and over 2,350 books and book series … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 16 publications
(18 reference statements)
0
4
0
Order By: Relevance
“…In selective harmonic elimination methods, the triplen harmonics are deliberately not included in the selected harmonic orders for elimination, since they will automatically be cancelled from the line-to-line voltage and, consequently, from the load phase voltage [20], [21]. In THD minimization methods, however, this fact is ignored, and therefore, minimization of the THD of the phase voltage does not necessary result in minimum THD in the line-to-line voltage.…”
Section: Introductionmentioning
confidence: 97%
“…In selective harmonic elimination methods, the triplen harmonics are deliberately not included in the selected harmonic orders for elimination, since they will automatically be cancelled from the line-to-line voltage and, consequently, from the load phase voltage [20], [21]. In THD minimization methods, however, this fact is ignored, and therefore, minimization of the THD of the phase voltage does not necessary result in minimum THD in the line-to-line voltage.…”
Section: Introductionmentioning
confidence: 97%
“…According to the statement of DG in distribution network, this paper analyses a three-phase PV power system connected to a LV distribution grid as described in Rivera et al (2011); Xiao et al (2013). The PV system is based on a three-phase Y-connected cascaded H-bridge topology (Fathi et al, 2009;Jaafar et al, 2008). The analytical model of the PV system and a control strategy for unbalanced operations of the PV system is proposed in this paper.…”
Section: Compel 346mentioning
confidence: 99%
“…Moreover, the equal amplitude of the DC link voltage is considered in most of the SHE-PWM methods, but practically it is not acceptable [20]. The DC link voltage is adjusted suitably to get a quality output of the multilevel inverter [21]. In the same way, the quality of the output waveform of the converter can be improved by adjusting the amplitude of the DC link voltage of the cascaded H-Bridge topology.…”
Section: Introductionmentioning
confidence: 99%