2013 IEEE Energy Conversion Congress and Exposition 2013
DOI: 10.1109/ecce.2013.6646723
|View full text |Cite
|
Sign up to set email alerts
|

Optimum number of cascaded cells for high-power medium-voltage multilevel converters

Abstract: When power electronic systems are connected to the medium-voltage grid, often multilevel topologies consisting of a number of cascaded converter cells are considered. For a given grid voltage level, either few cells featuring semiconductors with high blocking voltage capability or many cells using lowvoltage semiconductors can be employed. This paper proposes efficiency/power density (η-ρ) Pareto analysis to comprehensively identify the optimum number of cascaded cells. Recent advances in silicon carbide (SiC)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
31
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 53 publications
(33 citation statements)
references
References 35 publications
(34 reference statements)
2
31
0
Order By: Relevance
“…In literature works addressing the reliability of modular power converter structure can be found [5], and the findings support the thesis that The authors are with the Chair of Power Electronics, ChristianAlbrechts Universitt zu Kiel 24118 Kiel, Germany (e-mail: ma@tf.uni-kiel.de; vir@tf.uni-kiel.de; gibu@tf.uni-kiel.de; liserre@ieee.org. modular architectures allow increasing the efficiency.…”
Section: Introductionsupporting
confidence: 74%
“…In literature works addressing the reliability of modular power converter structure can be found [5], and the findings support the thesis that The authors are with the Chair of Power Electronics, ChristianAlbrechts Universitt zu Kiel 24118 Kiel, Germany (e-mail: ma@tf.uni-kiel.de; vir@tf.uni-kiel.de; gibu@tf.uni-kiel.de; liserre@ieee.org. modular architectures allow increasing the efficiency.…”
Section: Introductionsupporting
confidence: 74%
“…For example, solid-state transformers (SST) and dc distribution systems, which are high voltage (HV) or medium voltage (MV) applications, essentially require the use of multilevel topologies [3][4][5][6][7]. In multilevel topologies, three-level neutral-point-clamped (NPC) inverters have been widely used in MV and HV applications.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, the evaluation of the heat sink volume in IGBTs with the voltage rating of which varies from 600 V to 6.5 kV has been also discussed (29) . However, the formulae of the semiconductor losses in the H-bridge cell type MMC have not been thoroughly clarified.…”
Section: Introductionmentioning
confidence: 99%