2022
DOI: 10.3390/app12052708
|View full text |Cite
|
Sign up to set email alerts
|

Optimizing the Minimum Detectable Difference of Gamma Camera SPECT Images via the Taguchi Analysis: A Feasibility Study with a V-Shaped Slit Gauge

Abstract: This study tried to propose an innovated idea of solidifying the resolution of gamma camera in routine quality control and recommended a quantified index as minimum detectable difference (MDD) of gamma camera SPECT images using the Taguchi analysis and an indigenous V-shaped slit gauge. The gauge was customized to fulfill the quantitative requirement of the Taguchi analysis. The MDD among slit gauge of derived SPECT image was calculated from two overlapped peak profiles collected from a tangent slice of the V-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 22 publications
(31 reference statements)
0
1
0
Order By: Relevance
“…Pendekatan metode ini mengaplikasikan Design of Experiments (DOE), yang merupakan elemen krusial dalam upaya mencapai mutu superior dan menggali alternatif solusi yang efektif (Ke et al, 2022). DOE berfungsi untuk menganalisis berbagai variasi Jurnal Inovasi Daerah, Vol 2, No.…”
Section: Pendahuluanunclassified
“…Pendekatan metode ini mengaplikasikan Design of Experiments (DOE), yang merupakan elemen krusial dalam upaya mencapai mutu superior dan menggali alternatif solusi yang efektif (Ke et al, 2022). DOE berfungsi untuk menganalisis berbagai variasi Jurnal Inovasi Daerah, Vol 2, No.…”
Section: Pendahuluanunclassified
“…Image quality is related to system performance and can be expressed by several physical parameters. The most important are related to the imaging system, i.e., contrast, spatial resolution, sensitivity, and uniformity [1][2][3][4][5][6][7]. When performing MPI on a SPECT system with NaI-crystal and parallel-hole collimators, only a small portion of the detector area is used.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the contributions of particular risk factors or their cross-interactions can be evaluated and ranked by their importance [ 1 , 2 , 3 , 4 , 5 , 6 ]. Unlike the Taguchi optimization algorithm, which is used to optimize one purpose from a combination of multiple factors [ 7 , 8 , 9 , 10 ], IPA directly estimates the expectation value from a group of data. Thus, IPA provides more quantified information than Taguchi’s approach, suggesting just the optimal combination of factors.…”
Section: Introductionmentioning
confidence: 99%