2010
DOI: 10.1007/s12194-010-0105-y
|View full text |Cite
|
Sign up to set email alerts
|

Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography

Abstract: Our aim in this study was to determine an optimal delay time of hepatic arterial phase (HAP) imaging of hypervascular hepatocellular carcinomas (HCCs) in dynamic contrast-enhanced MDCT (DCE-CT) by use of the bolus-tracking method. The time-enhancement curves (TECs) of the aorta and the contrast of the hepatic arterial and portal system (APC) in the pharmacokinetic analysis were calculated. The clinical study included 41 patients with known or suspected HCC who underwent DCE-CT. The TECs of the aorta and the tu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
14
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 43 publications
(73 reference statements)
1
14
0
Order By: Relevance
“…The total amount of contrast to a patient can affect the degree of organ enhancement [2,3,7,13], while changes in the flow rate can affect the magnitude and timing of peak vascular enhancement [2,3]. The results of this study revealed 12.2 % of administrations from a large data base deviated from the prescribed amounts by more than 10 % and that 97 % of these deviations involved delivering too much contrast rather than too little based on the protocol.…”
Section: Discussionmentioning
confidence: 83%
See 4 more Smart Citations
“…The total amount of contrast to a patient can affect the degree of organ enhancement [2,3,7,13], while changes in the flow rate can affect the magnitude and timing of peak vascular enhancement [2,3]. The results of this study revealed 12.2 % of administrations from a large data base deviated from the prescribed amounts by more than 10 % and that 97 % of these deviations involved delivering too much contrast rather than too little based on the protocol.…”
Section: Discussionmentioning
confidence: 83%
“…Contrast flow rate has been seen to have a large effect on study quality as it changes the timing of contrast enhancement [2,3]. Limiting this variable as much as possible would allow for more consistent phases of enhancement, especially during multiphase exams [7].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations