Optimizing radiation exposure in screening of body packing: image quality and diagnostic acceptability of an 80 kVp protocol with automated tube current modulation

Abstract: The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 19 publications
(37 reference statements)
1
2
0
Order By: Relevance
“…It is not known whether they were body packers or body stuffers. Our profile of young and male body packers matches that reported in other studies from several nations [13][14][15][16][17]. In addition, these patients ingested very different types of content.…”
Section: Discussionsupporting
confidence: 85%
“…It is not known whether they were body packers or body stuffers. Our profile of young and male body packers matches that reported in other studies from several nations [13][14][15][16][17]. In addition, these patients ingested very different types of content.…”
Section: Discussionsupporting
confidence: 85%
“…We found an effective dose of 0.11 mSv to be sufficient for the detection of cocaine body packets. Prior studies evaluated body packing CT protocols with reduced radiation dose that are used in clinical routine and reported diagnostic image quality for CT protocols with an effective dose of 1.06–2.05 mSv [ 5 , 8 , 11 , 18 , 19 ] which is close to an abdominal radiography. However, due to the clinical setting of previous studies, a radiation-dose threshold could not be determined.…”
Section: Discussionmentioning
confidence: 99%
“…Rotation time was 0.5 s and collimation was 0.6 mm. Image quality of the CT protocol has been previously validated [ 11 ]. All scans were performed without oral or intra venous contrast media.…”
Section: Patient Materials and Methodsmentioning
confidence: 99%