Optimizing PEEP by Electrical Impedance Tomography in a Porcine Animal Model of ARDS

Abstract: PEEP setting by EIT facilitates a more individual ventilation therapy. However, in our relatively short ARDS observation period of 24 h, no significant differences appeared in common clinical parameters compared with a control group.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 45 publications
1
15
0
Order By: Relevance
“…As the only bedside tool available, retrospective evaluations of EIT-guided PEEP titration confirmed its feasibility [15, 16, 20, 23, 31]. Two prospective outcome studies were conducted in lavaged pigs, one of them confirming that EIT-guided PEEP selection was superior to the ARDSnet table [17, 32]. The ARDSnet table recommends PEEP according to FiO 2 levels, which is less individualized than selection based on lung mechanics, blood gases or imaging.…”
Section: Discussionmentioning
confidence: 99%
“…As the only bedside tool available, retrospective evaluations of EIT-guided PEEP titration confirmed its feasibility [15, 16, 20, 23, 31]. Two prospective outcome studies were conducted in lavaged pigs, one of them confirming that EIT-guided PEEP selection was superior to the ARDSnet table [17, 32]. The ARDSnet table recommends PEEP according to FiO 2 levels, which is less individualized than selection based on lung mechanics, blood gases or imaging.…”
Section: Discussionmentioning
confidence: 99%
“…Initially, Zhao et al were able to demonstrate that the GI index may be useful to guide PEEP settings [25]. The idea of PEEP guidance by GI index was taken up in experimental and clinical studies several times [26,27]. Overall, the GI index focuses on spatial heterogeneity within the lung.…”
Section: Discussionmentioning
confidence: 99%
“…The assessment of regional overdistension and atelectasis can be visualized using EIT during changes in PEEP and has been validated by histological examination of lung tissue [28]. An animal study used by Wolf et al was the first prospective study wherein EIT guided ventilator settings were used [18], followed by other animal and human studies [22, 29]. …”
Section: Discussionmentioning
confidence: 99%