2016
DOI: 10.1016/j.ultras.2015.09.007
|View full text |Cite
|
Sign up to set email alerts
|

Optimized ultrasonic attenuation measures for non-homogeneous materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…In this work, different sinusoidal tone burst signals (which produce narrowband excitation) varying in frequency [39,44,47,70,76] were launched in the tested plate and then every received spectrogram was combined into one [37] (hereafter, the combined spectrogram). The mathematical model of the transmitted sinusoidal tone burst signals is shown in Equation (9) [77]:xn(t)=A·sin(2πfnt)·rect(ttrueNc2fntrueNcfn), where A is the signal amplitude, fn is the driving frequency, Nc the number of cycles and rect(·) is the rectangular function.…”
Section: Mathematical Backgroundmentioning
confidence: 99%
“…In this work, different sinusoidal tone burst signals (which produce narrowband excitation) varying in frequency [39,44,47,70,76] were launched in the tested plate and then every received spectrogram was combined into one [37] (hereafter, the combined spectrogram). The mathematical model of the transmitted sinusoidal tone burst signals is shown in Equation (9) [77]:xn(t)=A·sin(2πfnt)·rect(ttrueNc2fntrueNcfn), where A is the signal amplitude, fn is the driving frequency, Nc the number of cycles and rect(·) is the rectangular function.…”
Section: Mathematical Backgroundmentioning
confidence: 99%
“…This analysis considers the frequency response of the equipment used in the experiment. For further details about the calibration process and the computation of the ESD of a chirp signal, see [16].…”
Section: Time and Frequency Dependent Parametersmentioning
confidence: 99%
“…The disadvantage of this kind of test is the fact that the mechanical properties of the GRC plates change quickly during the test, and it is difficult to inject various signals with different frequencies to cover a wide spectrum. To solve this problem, the authors have also recently published a study of the suitability of broadband signals, comparing different methods and signals to obtain a reliable method to acquire the information of a wide bandwidth with one single signal (chirp) [16]. This procedure permits monitoring a huge range of situations where the test-time has critical effects.…”
Section: Introductionmentioning
confidence: 99%
“…The transmitted signals can be narrowband ( [8,[13][14][15]) or broadband ([6, 8, 16]). If the attenuation of the material and the sensitivity of measurement equipment allow the use of broadband signals, then the combination of this kind of measurement and suitable signal processing will result in an optimal estimate of α( f ) with a minimum of measurement time [17]. Although these studies have focused on contact measures, some work has been carried out using airborne non-contact ultrasound or air-coupled ultrasound [18,19].…”
Section: Introductionmentioning
confidence: 99%