Optimization to Limit the Effects of Underloaded Generator Sets in Stand-Alone Hybrid Ship Grids

Abstract: For the safety of the supply, diesel generator (DG) sets are used in various stand-alone power systems using variable-speed generators. The stand-alone hybrid grid system presented in this article, with a wind generator and a diesel generator, but also the system of a ship’s network, serves as an example. To ensure the safety of the ship’s exploitation, the parallel operation of two stand-alone power supplies is required. In parallel operation with the required symmetrical active power load (regardless of the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…Analytical and modeling tests were conducted on the basis of the analysis of electromagnetic processes in quasi-steady modes, described in the classical works of scientists in the field of electrical engineering, electromechanics and automatic control theory [ 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 ].…”
Section: Functional Diagram Of the ‘Shore To Ship’ (Sts) Mechatronmentioning
confidence: 99%
See 1 more Smart Citation
“…Analytical and modeling tests were conducted on the basis of the analysis of electromagnetic processes in quasi-steady modes, described in the classical works of scientists in the field of electrical engineering, electromechanics and automatic control theory [ 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 ].…”
Section: Functional Diagram Of the ‘Shore To Ship’ (Sts) Mechatronmentioning
confidence: 99%
“…In the active converter connected to the network via a parametric choke ( r 1 , X 1 ), current control is usually realized when the current in CA_1 is generated with the use of negative feedback from the transmitter [ 28 , 29 ]. In such a case, the set (control) signals are network currents ( I x , I y ) in the x and y axes.…”
Section: Analysis Of the Sts System With Current Controlmentioning
confidence: 99%
“…The inductive and active resistance in the equivalent circuit are internal parameters of the machine. The mathematical description of PMSG is carried out in the synchronously rotating coordinate system (x,y) using the generalized (resulting) vector method [9,12,16] and the "main component " method [3,8]. This mathematical description looks like:…”
Section: Mathematical Description Of Pmsg / Matematički Opis Pmsg-amentioning
confidence: 99%
“…Then from geometrical constructions ( Figure 6), it is possible to defi ne longitudinal and transverse components of currents at which reactive power at the PMSG output is equal to zero. Calculation of energy characteristics of the generator at such control is carried out by equations (7,8,9).…”
Section: Energy Characteristics Of An Optimized Shaft Generator With mentioning
confidence: 99%
“…Applying DGs in hybrid systems along with other electric power sources also causes the diesel engine to operate at a reduced load for long periods [1]. This leads to "wet stacking," which increases the commonly known cost of engine exploitation and unfavorable environmental phenomena [2]. Furthermore, operating a DG set at a load level less than 30% of maximum output is the key trigger behind the polishing and glazing phenomena of cylinders [3][4][5].…”
Section: Introductionmentioning
confidence: 99%