2023
DOI: 10.1088/1748-0221/18/09/p09002
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of WLS fiber readout for the HERD calorimeter

X. Liu,
Z. Quan,
Y.W. Dong
et al.

Abstract: A novel 3-D calorimeter, composed of about 7500 LYSO cubes, is the key and crucial detector of the High Energy cosmic-Radiation Detection (HERD) facility to be installed onboard the China Space Station. Energy deposition from cosmic ray in each LYSO cube is translated by multiple wavelength shifting (WLS) fibers for multi-range data acquisition and real-time triggering. In this study, various methods of surface finish and encapsulation of the LYSO cube were investigated to optimize the amplitude from the WLS … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 15 publications
0
1
0
Order By: Relevance
“…It is homogeneous, isotropic, 3D segmented, deep (about 55 radiation length and 3 hadronic interaction length), with a very large geometric factor and a good energy resolution (about 2.5% for electrons and less than 30% for protons). The calorimeter has a double read-out, indeed the scintillation light produced by every crystal is detected by two independent systems: one based on the use of WaveLength Shifting Fibers coupled to Intensified Scientific CMOS (WLSF system) [11], and one based on the use of two photodiodes with different active areas (PD system) [12] [13] [14]. Both read-out systems should have an incredibly high dynamic range: bigger than 10 7 , in order to acquire signal from the minimum ionizing particle for in-orbit calibration, up to 250 TeV, necessary in order to measure showers induced by PeV protons.…”
Section: Pos(taup2023)142mentioning
confidence: 99%
“…It is homogeneous, isotropic, 3D segmented, deep (about 55 radiation length and 3 hadronic interaction length), with a very large geometric factor and a good energy resolution (about 2.5% for electrons and less than 30% for protons). The calorimeter has a double read-out, indeed the scintillation light produced by every crystal is detected by two independent systems: one based on the use of WaveLength Shifting Fibers coupled to Intensified Scientific CMOS (WLSF system) [11], and one based on the use of two photodiodes with different active areas (PD system) [12] [13] [14]. Both read-out systems should have an incredibly high dynamic range: bigger than 10 7 , in order to acquire signal from the minimum ionizing particle for in-orbit calibration, up to 250 TeV, necessary in order to measure showers induced by PeV protons.…”
Section: Pos(taup2023)142mentioning
confidence: 99%