2020
DOI: 10.1016/j.ultrasmedbio.2020.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Ultrasound Backscatter Spectroscopy to Assess Neurotoxic Effects of Anesthesia in the Newborn Non-human Primate Brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 75 publications
0
4
0
Order By: Relevance
“…Furthermore, the rejection of a large number of data is common in the initial steps of the development of quantitative imaging. For example, Castañeda-Martinez et al [53] rejected data from 11 out of 16 subjects while implementing Ultrasound Backscatter Spectroscopy in the neonatal brain. Also, Wang et al [54] rejected 50% of measurements when using shear wave elasticity imaging in the liver.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the rejection of a large number of data is common in the initial steps of the development of quantitative imaging. For example, Castañeda-Martinez et al [53] rejected data from 11 out of 16 subjects while implementing Ultrasound Backscatter Spectroscopy in the neonatal brain. Also, Wang et al [54] rejected 50% of measurements when using shear wave elasticity imaging in the liver.…”
Section: Discussionmentioning
confidence: 99%
“…All data processing was done in custom software programmed in MATLAB R2021a (The MathWorks, Natick, MA). A parametric imaging strategy was followed to process the data, which consists of scanning an entire region of interest (ROI), that is, the entire image of the lesion, with a parameter estimation region (PER) 16,38,42,43 . From the RF signals contained within the PER, a single power spectrum was obtained from which a single backscatter coefficient was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…From the fit, the value of the noise level at 6 MHz (approximate spectral center frequency) was estimated. The analysis bandwidth was defined by the interval of frequencies in which the value of the spectrum was 10 dB above the estimated value of the noise at 6 MHz 43 . In this way, the minimum frequency, maximum frequency, and central frequency (average between the minimum and maximum frequencies) were obtained for the power spectrum of the references and of all the acquisitions obtained from the 29 lesions.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation