2018
DOI: 10.17265/1934-7359/2018.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of the Traditional Method for Creating a Weather Simulation File: The Pelotas.epw Case

Abstract: The basic assumption of an energy-efficient project is the proper relation with the local climatic context. To analyse a building's performance before its construction, it is necessary that the object to be designed is recreated in a virtual environment, to evaluate its thermal balance. In order to recreate this virtual environment, it is necessary to use computer programs, and that requires a file composed of a weather database organized hourly in a specific year and defined, in the case of this article, from… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
4

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 4 publications
0
5
0
4
Order By: Relevance
“…The climatic data for 10 years (from 2006 to 2015) were provided by Pelotas’ Agroclimatology Station, in partnership with the Brazilian Agricultural Research Corporation (EMBRAPA), 71 and after analysis, the weather file was developed based on the average monthly temperatures of 2014 using the TRY method. 72 Table 5 illustrates the climatic data for the city of Pelotas.
Figure 3.Monthly climatic data for the city of Pelotas. 71
…”
Section: Methodsmentioning
confidence: 99%
“…The climatic data for 10 years (from 2006 to 2015) were provided by Pelotas’ Agroclimatology Station, in partnership with the Brazilian Agricultural Research Corporation (EMBRAPA), 71 and after analysis, the weather file was developed based on the average monthly temperatures of 2014 using the TRY method. 72 Table 5 illustrates the climatic data for the city of Pelotas.
Figure 3.Monthly climatic data for the city of Pelotas. 71
…”
Section: Methodsmentioning
confidence: 99%
“…Para realizar as simulações comparativas entre os dados coletados nos ensaios e os dados do programa WUFI Pro 6.5, foi adotado como critério a escolha de um tijolo cerâmico da base de dados com as características mais próximas possíveis às da norma ABNT NBR 15220 (2003), conforme Tabela 1. Para as condições internas foi utilizado o arquivo criado anteriormente no programa EnergyPlus 9.0, e para o clima externo, foi utilizado um arquivo climático para a cidade de Pelotas-RS (LEITZKE et al, 2018). A chuva dirigida foi considerada conforme a norma ASHRAE Standard 160 (ASHRAE, 2009), segundo Zanoni et al (2018).…”
Section: Etapa 3: Simulação Computacionalunclassified
“…The model settings were configured in the IDF editor of version 8.3 of EnergyPlus software. Occupancy and lighting schedules were configured according to the RTQ-R (Quality Technical Regulation for the energy efficiency level for residential buildings) (INMETRO, 2010). RTQ-R is a Brazilian residential building energy efficiency regulation.…”
Section: Building Modeling and Simulationmentioning
confidence: 99%