2007
DOI: 10.1111/j.1600-0846.2007.00235.x
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of the skin multiple analyte profile bioanalytical method for determination of skin biomarkers from D‐Squame® tape samples

Abstract: These data enable us to better manage SkinMAP studies and interpret their results. The use of 1.5 mL PBS containing 0.2% SDS and 0.5% PG with 30 min sonication at low (near 4 degrees C) temperature is optimal for the quantitation of a range of SkinMAP analytes. In order to protect researchers from obtaining inflated false positive rates, it is crucial to design such studies and analyze the data using appropriate statistical methodology, especially for those studies involving only a small number of subjects.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
37
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(37 citation statements)
references
References 40 publications
0
37
0
Order By: Relevance
“…Biomarkers were extracted in PBS buffer, 0.2% SDS, and 0.5% propylene glycol and sonicated for 60 min at 4°C. Keratin 1,10,11 (as a mixture), keratin 6, involucrin, fibronectin, cortisol, and albumin were quantified using Human Skin Panel Lincoplex Kit microsphere beads (Linco Research, Inc., St. Charles, MO) (13). IL1␣, IL1␤, TNF␣, IL6, MCP1, IL8, IL1RA, INF␥, and IP10 were determined using human cytokine bead-based arrays (Linco Research) with a Bio-Plex multiplex suspension system (BioRad Laboratories, Hercules, CA).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Biomarkers were extracted in PBS buffer, 0.2% SDS, and 0.5% propylene glycol and sonicated for 60 min at 4°C. Keratin 1,10,11 (as a mixture), keratin 6, involucrin, fibronectin, cortisol, and albumin were quantified using Human Skin Panel Lincoplex Kit microsphere beads (Linco Research, Inc., St. Charles, MO) (13). IL1␣, IL1␤, TNF␣, IL6, MCP1, IL8, IL1RA, INF␥, and IP10 were determined using human cytokine bead-based arrays (Linco Research) with a Bio-Plex multiplex suspension system (BioRad Laboratories, Hercules, CA).…”
Section: Methodsmentioning
confidence: 99%
“…Central to this approach is the application of a new noninvasive sampling method (13), which simultaneously determines multiple factors critical for the development of epidermal innate immune function. The technique analyzes biomarkers from the outermost SC eliminating the need for invasive tissue biopsies.…”
mentioning
confidence: 99%
“…After compression of the tape for 3 seconds, a Pulnix Tm-7CN monochrome CCD camera (Pulnix America Inc., Sunnyvale, CA, USA) and RGB monitor (PVM 1342Q; Sony Co., Tokyo, Japan) were used for measurement of the distribution and density of attached keratinocytes. This result was analyzed using an image analyzer (AIC Inc., Princeton, NJ, USA), and desquamation index (DI) and scaling index (SI) were calculated using this mathematical formula [9,10].…”
Section: Methodsmentioning
confidence: 99%
“…22À26 In contrast, variations in the gene encoding interleukin-1α (IL-1α) such as the presence of an IL1A-889 T allele have been shown to exert protective effects toward the development of manifest dermatitis that have been attributed to reduced IL-1α levels in the stratum corneum. 27,28 Genetic variations related to the skin barrier that have been found to contribute to increased susceptibility to irritant dermatitis include loss-of-function mutations in the gene encoding the epidermal differentiation protein filaggrin (FLG). The FLG mutations are the most important individual risk factor for atopic dermatitis known so far, 29À31 whereas individuals with atopic skin disease have been found to show enhanced responses to irritant damage.…”
Section: Delayed Acute Irritant Dermatitismentioning
confidence: 99%