Optimization of the parameters of a standard source of synchrotron radiation with strong magnetic field for calibration of ultraviolet plasma radiators and integral radiometer-dosimeters
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.