Optimization of the geometry and speed of a moving blocker system for cone‐beam computed tomography scatter correction

Abstract: Purpose X-ray scatter is a significant barrier to image quality improvements in cone-beam computed tomography (CBCT). A moving blocker-based strategy was previously proposed to simultaneously estimate scatter and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan. A blocker consisting of lead stripes is inserted between the x-ray source and the imaging object, and moves back and forth along the rotation axis during gantry rotation. While promising results were obtained in ou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 19 publications
(27 citation statements)
references
References 61 publications
1
26
0
Order By: Relevance
“…Instead of moving the beam blocker during the gantry rotation, they left the beam blocker stationary in the beam, but positioned it asymmetrically with respect to the central longitudinal line of the detector, so that at least one ray from its conjugate ray pair can be measured on the detector. Chen et al . also investigated a beam‐interrupting blocker for cone‐beam CT and optimized the blocker design in terms of slit separation and moving speed.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Instead of moving the beam blocker during the gantry rotation, they left the beam blocker stationary in the beam, but positioned it asymmetrically with respect to the central longitudinal line of the detector, so that at least one ray from its conjugate ray pair can be measured on the detector. Chen et al . also investigated a beam‐interrupting blocker for cone‐beam CT and optimized the blocker design in terms of slit separation and moving speed.…”
Section: Discussionmentioning
confidence: 99%
“…The drawback of this scheme is that current clinical CT systems cannot pulse the x‐ray source on the needed millisecond timeframe, since the thermal inertia of the cathode cannot be overcome quickly enough. For this reason, several previous works have proposed a different undersampling scheme that partially blocks the beam between the x‐ray tube and the patient to undersample along the detector row direction within each view . SparseCT is one such undersampling approach.…”
Section: Introductionmentioning
confidence: 99%
“…The convolution‐based method is computationally efficient, but the kernel must be predefined to be used and the results are sensitive to the kernel parameters . The measurement‐based methods typically use x‐ray beam‐blockers or beam stopper array . The measurement‐based methods are simple and efficient, and can achieve accurate scatter estimation without a prior knowledge of the target object.…”
Section: Introductionmentioning
confidence: 99%
“…However, secondary effects due to modulator penumbra and beam hardening may influence the scatter distribution. Recently, object model‐based approaches were introduced for scatter correction using energy‐resolved reprojection technique . Nevertheless, segmentation involving complex materials and structures may become a very challenging work.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation